Transdermal and Topical Delivery Systems - Product Development and Quality Considerations November 2019

Draft Level 1 Guidance

Not for implementation. Contains non-binding recommendations.

Docket Number:
FDA-2019-D-4447
Issued by:
Guidance Issuing Office
Center for Drug Evaluation and Research

This guidance provides recommendations to applicants and manufacturers of transdermal and topical delivery systems (TDS) regarding the pharmaceutical development and quality information to include in new drug applications (NDAs) and abbreviated new drug applications (ANDAs). , Specifically, the guidance discusses FDA’s current thinking on product design and pharmaceutical development, manufacturing process and control, and finished product control. It also addresses special considerations for areas where quality is closely tied to product performance and potential safety issues, such as adhesion failure and the impact of applied heat on drug delivery.


Submit Comments

You can submit online or written comments on any guidance at any time (see 21 CFR 10.115(g)(5))

If unable to submit comments online, please mail written comments to:

Dockets Management
Food and Drug Administration
5630 Fishers Lane, Rm 1061
Rockville, MD 20852

All written comments should be identified with this document's docket number: FDA-2019-D-4447.