1. Home
  2. Inspections, Compliance, Enforcement, and Criminal Investigations
  3. Compliance Actions and Activities
  4. Warning Letters
  5. Woorilife & Health - 672936 - 12/28/2023
  1. Warning Letters

WARNING LETTER

Woorilife & Health MARCS-CMS 672936 —


Delivery Method:
VIA UPS
Reference #:
320-24-14
Product:
Drugs

Recipient:
Recipient Name
Ho Dong Yang
Woorilife & Health

3 Biryong-ro 464beon-gil
Hwado-eup
Namyangju-si
Gyeonggi-do
12033
South Korea

Issuing Office:
Center for Drug Evaluation and Research | CDER

United States

Secondary Issuing Offices

United States


Warning Letter 320-24-14

December 28, 2023

Dear Ho Dong Yang:

Your facility is registered with the United States Food and Drug Administration (FDA) as a manufacturer of over the counter (OTC) drug products. FDA has reviewed the records you submitted in response to our February 8, 2023, and July 12, 2023, requests for records and other information pursuant to section 704(a)(4) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) for your facility, Woorilife & Health, FEI 3014653532, 3 Biryong-ro 464beon-gil, Hwado-eup, Namyangju Gyeonggi-do, South Korea.

This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations, parts 210 and 211 (21 CFR, parts 210 and 211).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding of drugs as described in your response to our 704(a)(4) request do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the FD&C Act (21 U.S.C. 351(a)(2)(B)).

Following review of records and other information provided pursuant to section 704(a)(4) of the FD&C Act, significant violations were observed including, but not limited to, the following:

1. Your firm failed to conduct at least one test to verify the identity of each component of a drug product (21 CFR 211.84(d)(1)).

You manufacture OTC drug products including toothpaste. Based on the records and information you provided, you did not demonstrate that you are adequately testing each shipment of each lot of the incoming components at high-risk of diethylene glycol (DEG) or ethylene glycol (EG) contamination. These include, but are not limited to, testing of glycerin, propylene glycol, and sorbitol solution, you use in manufacturing drug products to determine their appropriate identity. Identity testing for these and certain other high-risk drug components1 includes a limit test in the United States Pharmacopeia (USP) to ensure that the component meets the relevant safety limits for levels of DEG or EG. Because you did not perform identity testing on each shipment of each lot using the USP identification test that detects these hazardous impurities, you failed to assure the acceptability of these components for use in manufacture of your drug products.

The use of ingredients contaminated with DEG or EG has resulted in various lethal poisoning incidents in humans worldwide. See FDA’s guidance document Testing of Glycerin, Propylene Glycol, Maltitol Solution, Hydrogenated Starch Hydrolysate, Sorbitol Solution, and Other High-Risk Drug Components for Diethylene Glycol and Ethylene Glycol to help you meet the CGMP requirements when manufacturing drugs containing ingredients at high-risk for DEG or EG contamination at https://www.fda.gov/media/167974/download.

In response to this letter, provide:

  • A commitment to provide DEG and EG test results, no later than 30 working days from the date of this letter, from testing retains for all lots of high-risk drug components used in the manufacture of drug products. Alternatively, if a retain of a component lot is unavailable, perform retain sample testing of all implicated finished drug product batches for the presence of DEG and EG.
  • A full risk assessment for drug products that are within expiry which contain any ingredient at risk for DEG or EG contamination (including, but not limited to, glycerin). Take prompt and appropriate actions to determine the safety of all lots of the component(s) and any related drug product that could contain DEG or EG, including customer notifications and product recalls for any contaminated lots. Identify additional appropriate corrective actions and preventive actions (CAPA) that secure supply chains in the future, including, but not limited to, ensuring that all incoming raw material lots are from fully qualified manufacturers and free from unsafe impurities. Detail these actions in your response to this letter.
  • A description of how you will test each component lot for conformity with all appropriate specifications for identity, strength, quality, and purity. If you intend to accept any results from your supplier’s certificate of analysis (COA) instead of testing each component lot for strength, quality, and purity, specify how you will robustly establish the reliability of your supplier’s results through initial validation as well as periodic revalidation. In addition, include a commitment to always conduct at least one specific identity test for each incoming component lot. In the case of glycerin, propylene glycol, and certain additional high- risk components we note that this includes the performance of parts A, B, and C of the USP monograph.
  • The chemical quality control specifications you use to test each incoming lot of high-risk drug components to determine acceptability for use in manufacturing.
  • A comprehensive, independent review of your material system to determine whether all suppliers of components, containers, and closures, are each qualified and the materials are assigned appropriate expiration or retest dates. The review should also determine whether incoming material controls are adequate to prevent use of unsuitable components, containers, and closures.
  • A summary of your program for qualifying and overseeing contract facilities that test the drug products you manufacture.
  • A summary of results obtained from testing all components to evaluate the reliability of the COA from each component manufacturer. Include your standard operating procedure (SOP) that describes this COA validation program.

2. Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).

The records and information you provided demonstrate that your quality unit (QU) did not effectively exercise its responsibilities to oversee the quality of your drug manufacturing operations. Specifically, your QU did not adequately exercise its authority in the approval or rejection of components in your Materials System.

Your QU is responsible for fully exercising its authority and responsibilities. FDA is concerned that your QU may also not be conducting appropriate oversight regarding other CGMP operations, including Production, Facilities & Equipment, Laboratory Controls, and Packaging & Labelling Systems.

See FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https://www.fda.gov/media/71023/download.

In response to this letter, provide:

  • A comprehensive assessment and remediation plan to ensure your QU is given the authority and resources to effectively function. The assessment should also include, but not be limited to:

    o A determination of whether procedures used by your firm are robust and appropriate.
    o Provisions for QU oversight throughout your operations to evaluate adherence to appropriate practices
    o A complete and final review of each batch and its related information before the QU disposition decision
    o Oversight and approval of investigations and discharging of all other QU duties to ensure identity, strength, quality, and purity of all products.

CGMP Consultant Recommended

Based upon the nature of the violations we identified at your firm, you should engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements if your firm intends to resume manufacturing drugs for the U.S. market. The qualified consultant should also perform a comprehensive six-system audit2 of your entire operation for CGMP compliance and evaluate the completion and efficacy of your CAPA before you pursue resolution of your firm’s compliance status with FDA.

Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.

Conclusion

The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations.

FDA placed your firm on Import Alert 66-40 on December 27, 2023.

Correct any violations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to any violations.

Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may inspect your facility to verify that you have completed corrective actions to address any violations.

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 30 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with 3014653532 and ATTN: Kevin Maguire.

Sincerely,
/S/

Francis Godwin
Director
Office of Manufacturing Quality
Office of Compliance
Center for Drug Evaluation and Research
CC: U.S. Agent
Onbix Corp US
102 N G Street
Unit 105
Tacoma, WA 98403-2259
onbixUS@gmail.com for/

_______________________

1 Components with higher risk of DEG or EG contamination compared to other drug components.

2 i.e., Quality System, Facilities & Equipment System, Materials System, Production System, Packaging & Labeling System, and Laboratory Control System per FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations.

Back to Top