GUIDANCE DOCUMENT
Safety Assessment of Genome Editing in Human Gene Therapy Products Using Next-Generation Sequencing April 2026
Not for implementation. Contains non-binding recommendations.
- Docket Number:
- FDA-2026-D-1255
- Issued by:
-
Guidance Issuing OfficeCenter for Biologics Evaluation and Research, Office of Therapeutic Products
For a high-level overview of this guidance document, please watch this recorded webinar featuring Komudi Singh, PhD from FDA’s Office of Therapeutic Products.
This guidance provides recommendations for next-generation sequencing (NGS)-based methods used in nonclinical studies that will likely be needed to support initiation of clinical trials of investigational human genome editing (GE) products. These recommendations are in addition to the nonclinical, clinical, and CMC considerations discussed in the “Guidance for Industry: Human Gene Therapy Products Incorporating Human Genome Editing” dated January 2024 (January 2024 GE Guidance) (Ref. 1). Clinical development programs of human GE products should address both the risks associated with the gene therapy product itself as well as the additional risks associated with GE, including off-target editing and unintended changes to the genome for therapies targeting genetic diseases, including individualized therapies. For more information on clinical study design considerations and our science-based approach weighing the benefits and risks for human GE products, please refer to the January 2024 GE Guidance (Ref. 1). The recommendations in this guidance may guide stakeholders on designing nonclinical studies that use NGS methods and bioinformatics to evaluate the potential safety risks associated with off-target editing and loss of genome integrity in human GE products submitted in support of Investigational New Drug (IND) applications and Biologics License Applications (BLAs).
Submit Comments
You can submit online or written comments on any guidance at any time (see 21 CFR 10.115(g)(5))
If unable to submit comments online, please mail written comments to:
Dockets Management
Food and Drug Administration
5630 Fishers Lane, Rm 1061
Rockville, MD 20852
All written comments should be identified with this document's docket number: FDA-2026-D-1255.
Questions?
- Office of Communication, Outreach and Development (OCOD)
- Center for Biologics Evaluation and Research
Food and Drug Administration
10903 New Hampshire Ave WO71-3128
Silver Spring, MD 20993-0002
- ocod@fda.hhs.gov
- (800) 835-4709
- (240) 402-8010