Regulatory Science Tools Catalog
Regulatory Science Tools Catalog
The Regulatory Science Tools Catalog provides a peer-reviewed resource for use where standards and qualified Medical Device Development Tools (MDDTs) do not yet exist. These tools do not replace FDA-recognized standards or MDDTs. This catalog collates a variety of regulatory science tools that the FDA's Center for Devices and Radiological Health's (CDRH) Office of Science and Engineering Labs (OSEL) developed. If you are considering using a tool from this catalog in your marketing submissions, note that these tools have not been qualified as Medical Device Development Tools and the FDA has not evaluated the suitability of these tools within any specific context of use. You may request feedback or meetings for medical device submissions as part of the Q-Submission Program.
| Content: Main Image | Content: Title | Content: Detailed Description | ID | Link to Content |
|---|---|---|---|---|
|
WearGait-PD Longitudinal: Multi-Session Wearables Dataset for Gait in Parkinson’s Disease | This open-access longitudinal dataset contains raw inertial measurement unit (IMU) and sensorized insole data from individuals with Parkinson’s Disease (PD) synchronized to a gait walkway reference… | 430795 | /medical-devices/regulatory-science-tools-catalog/weargait-pd-longitudinal-multi-session-wearables-dataset-gait-parkinsons-disease |
|
Respirator Filtration Efficiency Calculator | The Respirator Filtration Efficiency Calculator is a conservative computational tool that assists stakeholders with the assessment of personal protective equipment (PPE) textile materials, namely… | 430794 | /medical-devices/regulatory-science-tools-catalog/respirator-filtration-efficiency-calculator |
|
Scanning Light Scattering Profiler (SLSP) Method for Quantitative Evaluation of Light Scattering in Intraocular Lens Implants | This regulatory science tool (RST) is a scanning light scattering profiler (SLSP) method for quantitative evaluation and nonclinical measurement of light scattering characteristics of both current… | 430793 | /medical-devices/regulatory-science-tools-catalog/scanning-light-scattering-profiler-slsp-method-quantitative-evaluation-light-scattering-intraocular |
|
Dual-Confocal Laser Caliper Method for Refractive Index and Thickness Measurements of Intraocular Lens Implants and Thin Films | This regulatory science tool (RST) is a dual-confocal laser caliper test method for refractive-index and thickness measurement of intraocular lens (IOL) implants and thin films | 430792 | /medical-devices/regulatory-science-tools-catalog/dual-confocal-laser-caliper-method-refractive-index-and-thickness-measurements-intraocular-lens |
|
Confocal Laser Methods for Quantitative Evaluation of Dioptric Power Characteristics of New-Technology Intraocular Lens Implants | This regulatory science tool (RST) is a confocal laser method to evaluate the dioptric power of commercially available and new-technology intraocular lens (NTIOL) implants. | 430791 | /medical-devices/regulatory-science-tools-catalog/confocal-laser-methods-quantitative-evaluation-dioptric-power-characteristics-new-technology |
|
Credibility Assessment Planning Tool for Model-Based Pulmonary Artery Reconstruction | This regulatory science tool (RST) provides an applied credibility assessment plan for a computational model-based, patient-specific surgical planning workflow that predicts optimal patch shape in… | 430790 | /medical-devices/regulatory-science-tools-catalog/credibility-assessment-planning-tool-model-based-pulmonary-artery-reconstruction |
|
Method for Leak Verification of Additively Manufactured Medical Devices Intended to Seal Air | This regulatory science tool (RST) is a Test Method to easily and efficiently assess the integrity of an additively manufactured (AM) medical device or component that is intended to seal air. | 430789 | /medical-devices/regulatory-science-tools-catalog/method-leak-verification-additively-manufactured-medical-devices-intended-seal-air |
|
Additively Manufactured Titanium – 6 Aluminum – 4 Vanadium Material Models | This regulatory science tool (RST) is a series of quasi-static isotropic material models for additively manufactured (AM) Titanium – 6 Aluminum – 4 Vanadium (Ti-6Al-4V) for use in finite element or… | 430787 | /medical-devices/regulatory-science-tools-catalog/additively-manufactured-titanium-6-aluminum-4-vanadium-material-models |
|
Digital Image Correlation (DIC) Target Speckle Size Calculator and Pattern Lookup Tool | This regulatory science tool (RST) is a browser-based resource for identifying a target speckle size and suitable patterning approach when planning digital image correlation (DIC) measurement studies… | 430788 | /medical-devices/regulatory-science-tools-catalog/digital-image-correlation-dic-target-speckle-size-calculator-and-pattern-lookup-tool |
|
Assessing Fit Factor and Breathability of Pediatric Facemasks | This regulatory science tool is a laboratory method for measuring fit-factor of pediatric facemasks. | 430785 | /medical-devices/regulatory-science-tools-catalog/assessing-fit-factor-and-breathability-pediatric-facemasks |
|
Large Diameter Flow Loop for In Vitro Dynamic Thrombogenicity Testing | This regulatory science tool (RST) provides a step-by-step protocol to design a 9.5 mm inner diameter recirculating flow loop test system and perform bench-top thrombogenicity testing of catheter-… | 430786 | /medical-devices/regulatory-science-tools-catalog/large-diameter-flow-loop-in-vitro-dynamic-thrombogenicity-testing |
|
3D Printing Strategies to Obtain Optically Clear Cardiovascular Anatomical Geometries for Flow Characterization | This tool is a how-to guide which demonstrates the design and manufacture of transparent cardiovascular anatomical models with optical access for visualization and measurement of fluid flow (ex.… | 430784 | /medical-devices/regulatory-science-tools-catalog/3d-printing-strategies-obtain-optically-clear-cardiovascular-anatomical-geometries-flow |
|
Phantom for Measuring Signal Sensitivity of Optical Coherence Tomography (OCT) Imaging Devices | This regulatory science tool (RST) is a phantom that enables assessment of a fundamental optical coherence tomography (OCT) system performance parameter. | 430783 | /medical-devices/regulatory-science-tools-catalog/phantom-measuring-signal-sensitivity-optical-coherence-tomography-oct-imaging-devices |
|
Blood-mimicking Dye Phantoms for Evaluating Photoacoustic Imaging Devices | This regulatory science tool is a lab method that may be helpful while evaluating Photoacoustic Imaging devices. | 430782 | /medical-devices/regulatory-science-tools-catalog/blood-mimicking-dye-phantoms-evaluating-photoacoustic-imaging-devices |
|
Photocytotoxicity Test Method for Fluorescence Imaging Products | This regulatory science tool (RST) is a method to evaluate the photochemical damage potential of products that include an optical imaging system and fluorescent contrast agent. | 430781 | /medical-devices/regulatory-science-tools-catalog/photocytotoxicity-test-method-fluorescence-imaging-products |
|
Accelerated Aging Test Method Incorporating Load Profiles for Primary Lithium Batteries in Active Implantable Medical Devices | This tool provides an accelerated aging test protocol for assessing pulse-induced capacity degradation in primary lithium batteries for Active Implantable Medical Devices (AIMDs). | 430779 | /medical-devices/regulatory-science-tools-catalog/accelerated-aging-test-method-incorporating-load-profiles-primary-lithium-batteries-active |
|
Electromagnetic Immunity Test Signals for Proximity Fields from 5G FR1 Wireless Communication Equipment | This tool describes a method for testing medical device electromagnetic immunity to proximity fields emitted by 5G FR1 wireless communication equipment. | 430780 | /medical-devices/regulatory-science-tools-catalog/electromagnetic-immunity-test-signals-proximity-fields-5g-fr1-wireless-communication-equipment |
|
Electromagnetic Immunity Test Method for Evaluating Device Exposure to Consumer Inductive Wireless Power Transfer (WPT) Systems | This Regulatory Science Tool (RST) is a lab method for testing medical device electromagnetic immunity to consumer-grade wireless power transfer (WPT) systems as part of assessing Electromagnetic… | 430778 | /medical-devices/regulatory-science-tools-catalog/electromagnetic-immunity-test-method-evaluating-device-exposure-consumer-inductive-wireless-power |
|
Computation of Physiologic Closed-Loop Controller Response Metrics | This regulatory science tool is a software tool that computes select controller response metrics relevant to physiologic closed-loop controlled (PCLC) medical devices. The tool accepts response data… | 430777 | /medical-devices/regulatory-science-tools-catalog/computation-physiologic-closed-loop-controller-response-metrics |
|
Method for Evaluating Volatile Organic Compound Emissions from Newly Manufactured Neonatal Incubators | This regulatory science tool (RST) is an air monitoring method that uses commercially available monitoring badges to evaluate volatile organic compound (VOC) emissions from newly manufactured… | 430776 | /medical-devices/regulatory-science-tools-catalog/method-evaluating-volatile-organic-compound-emissions-newly-manufactured-neonatal-incubators |
|
A Normative Dataset of Healthy Pediatric Cranial Computed Tomography (CT) Images | This regulatory science tool is a dataset of 100 healthy pediatric cranial computed tomography (CT) images with associated demographic data, intended to serve as a normative reference for developing… | 430775 | /medical-devices/regulatory-science-tools-catalog/normative-dataset-healthy-pediatric-cranial-computed-tomography-ct-images |
|
A 3D Quantitative Optical Coherence Tomography Angiography Method for Measuring Retinal Blood Flow in Humans | This regulatory science tool (RST) is a quantitative optical coherence tomography angiography (qOCTA) method to measure the absolute velocity of individual blood cells within retinal microvasculature… | 430774 | /medical-devices/regulatory-science-tools-catalog/3d-quantitative-optical-coherence-tomography-angiography-method-measuring-retinal-blood-flow-humans |
|
Computational Material Model of Polyurethane Bone Foam | This regulatory science tool (RST) is computational material model of polyurethane bone foam with a density of 20 pounds per cubic foot (PCF), which can be implemented in a finite element analysis… | 430773 | /medical-devices/regulatory-science-tools-catalog/computational-material-model-polyurethane-bone-foam |
|
AO-OCT Dataset on Human Photoreceptor-Retinal Pigment Epithelium Macular Topography | This regulatory science tool (RST) is an open-access dataset containing adaptive optics – optical coherence tomography (AO-OCT) images of the outer retina, along with the cell markings and… | 430771 | /medical-devices/regulatory-science-tools-catalog/ao-oct-dataset-human-photoreceptor-retinal-pigment-epithelium-macular-topography |
|
Phantom for Measuring Lateral Resolution and Contrast of Ophthalmic Adaptive Optics (AO) Imaging Systems | This regulatory science tool (RST) is a phantom that can be used for the assessment of certain fundamental performance parameters of adaptive optics (AO) imaging systems. | 430772 | /medical-devices/regulatory-science-tools-catalog/phantom-measuring-lateral-resolution-and-contrast-ophthalmic-adaptive-optics-ao-imaging-systems |
|
A 2D Quantitative Retinal Blood Flow Measurement Method in Humans with Multimodal Adaptive Optics Imaging | This regulatory science tool (RST) is a lab method for absolute vessel caliber and retinal blood flow velocity measurements in humans using a high-resolution (spatial and temporal) multimodal… | 430770 | /medical-devices/regulatory-science-tools-catalog/2d-quantitative-retinal-blood-flow-measurement-method-humans-multimodal-adaptive-optics-imaging |
|
Method for Assessing the Mechanical Durability of Anterior Vertebral Body Tethering Devices | This regulatory science tool presents a laboratory method to assess the mechanical integrity of anterior vertebral body tethering (AVBT) devices. | 430769 | /medical-devices/regulatory-science-tools-catalog/method-assessing-mechanical-durability-anterior-vertebral-body-tethering-devices |
|
Hemolysis Dataset for Validating Computational Fluid Dynamic (CFD) Simulation Through Generalized Cardiovascular Medical Device Geometries | The tool provides hemolysis data obtained from inter-laboratory bench experiments within generic and simplified device geometries. Modelers can use the data to perform early-stage evaluation of their… | 430768 | /medical-devices/regulatory-science-tools-catalog/hemolysis-dataset-validating-computational-fluid-dynamic-cfd-simulation-through-generalized |
|
Additively Manufactured Coupon for Characterizing Mechanical Performance of a Lattice in Tension | This regulatory science tool (RST) is a coupon designed for use in tensile testing additively manufactured lattices. | 430767 | /medical-devices/regulatory-science-tools-catalog/additively-manufactured-coupon-characterizing-mechanical-performance-lattice-tension |
|
Assessing DBT Image Quality with CDMAM 4.0 Phantom and DL-Based Model Observer | This regulatory science tool (RST) is a software suite that can assist with the objective task-based assessment of digital breast tomosynthesis (DBT) systems imaging performance that uses CDMAM 4.0… | 430765 | /medical-devices/regulatory-science-tools-catalog/assessing-dbt-image-quality-cdmam-40-phantom-and-dl-based-model-observer |
|
HistoGen: Histopathology Cell Nuclei Image Generation Tool | This regulatory science tool (RST) is a computational method that employs conditional denoising diffusion probabilistic model (DDPM) to generate synthetic histopathology images guided by nuclei… | 430766 | /medical-devices/regulatory-science-tools-catalog/histogen-histopathology-cell-nuclei-image-generation-tool |
|
T-SYNTH: A Knowledge-Based Dataset of Synthetic Breast Images | T-SYNTH is a synthetic dataset of paired DM (2D imaging) and DBT (3D imaging) images derived from a Knowledge Based (KB) model, with lesion bounding boxes and pixel-level tissue segmentations of a… | 430764 | /medical-devices/regulatory-science-tools-catalog/t-synth-knowledge-based-dataset-synthetic-breast-images |
|
Hybrid Simulation Framework for Breast CT Virtual Imaging Trials | This regulatory science tool (RST) is a software framework for generating hybrid breast CT images that combine simulated microcalcification clusters with real patient breast CT projection data. | 430762 | /medical-devices/regulatory-science-tools-catalog/hybrid-simulation-framework-breast-ct-virtual-imaging-trials |
|
SegAgree: Statistical Assessment of Agreement in Overlap-Based Performance Between an AI Segmentation Device and a Multi-Expert Human Panel | This regulatory science tool is a lab method that can be used for the assessment of agreement in overlap-based performance between an AI segmentation device and a multi-expert human panel. | 430763 | /medical-devices/regulatory-science-tools-catalog/segagree-statistical-assessment-agreement-overlap-based-performance-between-ai-segmentation-device |
|
Geometric Distortion Measurement Method on Video See-Through Augmented Reality Head-Mounted Displays | This regulatory science tool (RST) is a laboratory method for measuring the geometric distortion of the physical space observed with video see-through (VST) head-mounted displays (HMDs). | 430761 | /medical-devices/regulatory-science-tools-catalog/geometric-distortion-measurement-method-video-see-through-augmented-reality-head-mounted-displays |
|
Multi-QuCAD: Software to Evaluate Wait-Time-Savings and Delays Due to CADt Devices for Multiple Diseases in Clinical Workflow | Tools that quantify wait-time-saving benefits and delays for patients with positive diagnoses across various disease conditions due to the implementation of multiple Computer-Aided Triage and… | 430760 | /medical-devices/regulatory-science-tools-catalog/multi-qucad-software-evaluate-wait-time-savings-and-delays-due-cadt-devices-multiple-diseases |
|
Calzone: Evaluating the Calibration of Probabilistic Models | This regulatory science tool is a software for evaluating the calibration of models with probabilistic output. | 430759 | /medical-devices/regulatory-science-tools-catalog/calzone-evaluating-calibration-probabilistic-models |
|
COPE: Contrast Perception Evaluation on Head-Mounted Displays | This regulatory science tool is a laboratory method for the evaluation of contrast perception on head-mounted displays. | 430758 | /medical-devices/regulatory-science-tools-catalog/cope-contrast-perception-evaluation-head-mounted-displays |
|
MRI-IQ-ETK: Digital MRI Test Phantoms and Automated Image Quality Evaluation Toolkit for Assessing MRI Image Reconstruction Methods | MRI-IQ-ETK is a software toolkit that contains digital test phantom generation and automated image quality evaluation components intended to help assess the performance of MRI image reconstruction… | 430757 | /medical-devices/regulatory-science-tools-catalog/mri-iq-etk-digital-mri-test-phantoms-and-automated-image-quality-evaluation-toolkit-assessing-mri |
|
Pediatric IQ Phantoms: Digital Pediatric Image Quality Phantoms and Simulations for Evaluating CT Denoising Methods | The Pediatric IQ Phantoms tool is a dataset of virtual image quality phantoms in a range of diameters and their computed tomography (CT) images for assessing pediatric generalizability of CT… | 430756 | /medical-devices/regulatory-science-tools-catalog/pediatric-iq-phantoms-digital-pediatric-image-quality-phantoms-and-simulations-evaluating-ct |
|
Monastic Color Reproduction: A software Tool for Printing and Assessing the Monk Skin Tone Scale | This regulatory science tool is a lab method developed to assist end users in printing accurate Monk skin tone (MST) scales with consumer-grade color printers. | 430755 | /medical-devices/regulatory-science-tools-catalog/monastic-color-reproduction-software-tool-printing-and-assessing-monk-skin-tone-scale |
|
In Vitro Thrombogenicity Assessment of Blood-Contacting Materials Using Platelet and Coagulation Activation Molecular Biomarkers | This regulatory science tool (RST) is a benchtop test method for performing material-mediated thrombogenicity assessment of blood-contacting medical devices and materials using molecular biomarkers… | 430754 | /medical-devices/regulatory-science-tools-catalog/in-vitro-thrombogenicity-assessment-blood-contacting-materials-using-platelet-and-coagulation |
|
Dataset for the Development of Statistical Methods to Assess AI Model Performance: Images and Pathologist Annotations from the HTT Pilot Study | This regulatory science tool (RST) is a dataset of whole slide images and pathologist annotations for use in the development of new statistical methods. | 430752 | /medical-devices/regulatory-science-tools-catalog/dataset-development-statistical-methods-assess-ai-model-performance-images-and-pathologist |
|
Retina Phantom with Model Eye for Ophthalmic Optical Coherence Tomography (OCT) Devices | This regulatory science tool (RST) is a phantom that enables image quality assessment of ophthalmic optical coherence tomography (OCT) devices. | 430753 | /medical-devices/regulatory-science-tools-catalog/retina-phantom-model-eye-ophthalmic-optical-coherence-tomography-oct-devices |
|
Modified Adult Manikin Fit (MAMF) Test Method for Assessing Re-used and/or Decontaminated N95 Respirators | This regulatory science tool is a laboratory method for measuring fit-factor of re-used and/or decontaminated N95 respirators using adult manikins. | 430751 | /medical-devices/regulatory-science-tools-catalog/modified-adult-manikin-fit-mamf-test-method-assessing-re-used-andor-decontaminated-n95-respirators |
|
Method to Maintain Oxidative Capacity of Test Solutions for Oxidative Degradation Screening | This Regulatory Science Tool (RST) is a Laboratory Method outlining the use of a hydrogen peroxide solution to screen for oxidative degradation. This method allows for maintenance, monitoring and… | 430750 | /medical-devices/regulatory-science-tools-catalog/method-maintain-oxidative-capacity-test-solutions-oxidative-degradation-screening |
|
Point Spread Function Method for Spatial Resolution of Augmented Reality Head Mounted Displays | This regulatory science tool (RST) is a laboratory method for measuring the spatial resolution of optical see through augmented reality head mounted displays (AR HMDs) using point spread function… | 430749 | /medical-devices/regulatory-science-tools-catalog/point-spread-function-method-spatial-resolution-augmented-reality-head-mounted-displays |
|
Contrast Transfer Function Analysis Tool for Head Mounted Displays | This regulatory science tool (RST) is a laboratory method that calculates the Contrast Transfer Function (CTF) of Augmented Reality (AR) and Virtual Reality (VR) head mounted displays (HMDs) by… | 430748 | /medical-devices/regulatory-science-tools-catalog/contrast-transfer-function-analysis-tool-head-mounted-displays |
|
AO-OCTA Method and Dataset for Human Choriocapillaris Imaging | This regulatory science tool (RST) is an adaptive optics – optical coherence tomography angiography (AO-OCTA) method to resolve and quantify retinal vessels including the choriocapillaris (CC) in the… | 430747 | /medical-devices/regulatory-science-tools-catalog/ao-octa-method-and-dataset-human-choriocapillaris-imaging |
|
RAMAC: Registration based Automated Matching and Correspondence | Registration-based Automated Matching and Correspondence (RAMAC) is a tool that automatically identifies corresponding locations of landmarks across multiple images. | 430746 | /medical-devices/regulatory-science-tools-catalog/ramac-registration-based-automated-matching-and-correspondence |
|
Dynamic Headspace Gas Chromatography Mass Spectrometry (DHS-GC/MS) Method for Sensitive Detection of Volatiles in Saline Extracts | This regulatory science tool (RST) is a lab method that is intended to assist in the detection and quantification of volatiles in aqueous extracts using dynamic headspace gas chromatography-mass… | 430745 | /medical-devices/regulatory-science-tools-catalog/dynamic-headspace-gas-chromatography-mass-spectrometry-dhs-gcms-method-sensitive-detection-volatiles |
|
Measuring Flow Resistivity in Microfluidics-Based Medical Devices | This regulatory science tool is a lab method to measure flow resistivity in microfluidic-based devices, which may be used to identify flow-related failure modes (e.g., bubbles, leakage). | 430744 | /medical-devices/regulatory-science-tools-catalog/measuring-flow-resistivity-microfluidics-based-medical-devices |
|
Dataset of Infrared Facial and Oral Temperatures from Human Volunteers | This regulatory science tool (RST) is a dataset of facial and oral temperatures collected from infrared thermography of more than1000 human volunteers that may be helpful in evaluating the… | 430742 | /medical-devices/regulatory-science-tools-catalog/dataset-infrared-facial-and-oral-temperatures-human-volunteers |
|
TorchSurv: Deep Learning Tools for Survival Analysis | This regulatory science tool is an AI model tool used for developing and evaluating deep learning-based survival models. | 430743 | /medical-devices/regulatory-science-tools-catalog/torchsurv-deep-learning-tools-survival-analysis |
|
A Transfer Function Measurement System for MRI Safety Assessment of Implantable Medical Devices in Curved Trajectories | This regulatory science tool presents an apparatus to measure transfer functions (TF) of implantable medical devices in curved trajectories for MRI safety assessment. | 430741 | /medical-devices/regulatory-science-tools-catalog/transfer-function-measurement-system-mri-safety-assessment-implantable-medical-devices-curved |
|
Test Field Diversity Method Using a Tabletop E-field Generator: In vitro Transfer Function Model Validation for Implantable Medical Device Safety Assessment in 1.5T and 3T MRI | This regulatory science tool describes a method which can be utilized in the Magnetic Resonance Imaging (MRI) safety assessment of implantable medical devices to assist in the prediction of potential… | 430740 | /medical-devices/regulatory-science-tools-catalog/test-field-diversity-method-using-tabletop-e-field-generator-in-vitro-transfer-function-model |
|
A Link-Level Traffic Modeling Method for Networked Medical Extended Reality (MXR) Applications | This regulatory science tool is a method that models the link-level traffic patterns in medical extended reality (MXR) applications, which is intended to help recognize application-specific data… | 430739 | /medical-devices/regulatory-science-tools-catalog/link-level-traffic-modeling-method-networked-medical-extended-reality-mxr-applications |
|
Computational Model for Li/SVO-CFx Batteries used in Implantable Medical Devices | This regulatory science tool (RST) is a computational model for predicting implantable lithium battery temperature, remaining capacity and longevity. | 430738 | /medical-devices/regulatory-science-tools-catalog/computational-model-lisvo-cfx-batteries-used-implantable-medical-devices |
|
DxGoals: A Software Tool for Determining, Visualizing, and Analyzing Performance Goals for Diagnostic Test Classification Accuracy | DxGoals is a freely-accessible, RShiny software application that is intended to determine and visualize performance goals for common diagnostic test classification accuracy metrics including… | 430737 | /medical-devices/regulatory-science-tools-catalog/dxgoals-software-tool-determining-visualizing-and-analyzing-performance-goals-diagnostic-test |
|
The Linear Fit Tool (LiFT) for Orthopedic Device Testing | This regulatory science tool (RST) is a MATLAB script that automates the determination of stiffness from the slope of a linear region from mechanical test data using an algorithm that is in… | 430736 | /medical-devices/regulatory-science-tools-catalog/linear-fit-tool-lift-orthopedic-device-testing |
|
A Mathematical Model of the Cardiovascular System Response to Fluid Perturbation | This regulatory science tool is a mathematical model of the cardiovascular system response to fluid perturbations and includes a cohort generation tool to simulate virtual subjects as part of non-… | 430733 | /medical-devices/regulatory-science-tools-catalog/mathematical-model-cardiovascular-system-response-fluid-perturbation |
|
DomID: Deep Unsupervised Clustering Algorithms | DomID is a Python package offering a suite of unsupervised deep learning algorithms specifically designed for clustering medical image datasets. The primary goal is to identify subgroups that have… | 430734 | /medical-devices/regulatory-science-tools-catalog/domid-deep-unsupervised-clustering-algorithms |
|
Extract Preparation in Chemical Characterization Studies – Evaporation | The Evaporation tool provides a predictive model for estimation of the recovery of analytes in chemical characterization studies following concentration through rotary evaporation or nitrogen… | 430735 | /medical-devices/regulatory-science-tools-catalog/extract-preparation-chemical-characterization-studies-evaporation |
|
SegVal-WSI: Whole Slide Image Segmentation Algorithm Performance Assessment Tool | This regulatory science tool (RST) is a software program written in Python for performance assessment of segmentation algorithms applied to digital pathology whole slide images (WSIs). | 430732 | /medical-devices/regulatory-science-tools-catalog/segval-wsi-whole-slide-image-segmentation-algorithm-performance-assessment-tool |
|
GPU-accelerated Monte Carlo X-ray Simulation Software for Evaluating Medical Imaging Devices with Photon Counting Detectors (MCGPUv1.3_PCD) | This regulatory science tool is a computer model intended to support evaluation of photon counting detectors (PCDs) during the product development phase by generating in-silico X-ray projections of… | 430730 | /medical-devices/regulatory-science-tools-catalog/gpu-accelerated-monte-carlo-x-ray-simulation-software-evaluating-medical-imaging-devices-photon |
|
PyBDC: Python Breast Dosage Calculator | This regulatory science tool is a Python toolkit for calculating the radiation deposited dose for breast computed tomography (CT). It features a GUI that estimates the mean glandular dose based on… | 430731 | /medical-devices/regulatory-science-tools-catalog/pybdc-python-breast-dosage-calculator |
|
sFRC for Detecting Hallucinations in Medical Image Restoration | sFRC (scanning Fourier Ring Correlation) is a tool that compares radiological images from AI or iterative-based image restoration algorithms against those from standard-of-care analytical algorithms… | 430729 | /medical-devices/regulatory-science-tools-catalog/sfrc-detecting-hallucinations-medical-image-restoration |
|
bias.myti.report | This regulatory science tool presents two methods to amplify Artificial Intelligence (AI) / Machine Learning (ML) model bias to enable the evaluation of bias mitigation methods on models with varying… | 430728 | /medical-devices/regulatory-science-tools-catalog/biasmytireport |
|
DRAGen: Decision Region Analysis for Generalizability | This regulatory science tool presents a method (DRAGen) that identifies the types of errors which Artificial Intelligence (AI) / Machine Learning (ML) medical image classification algorithms might… | 430727 | /medical-devices/regulatory-science-tools-catalog/dragen-decision-region-analysis-generalizability |
|
Pediatric Plates and Screws used for Bone Fixation: An Engineering Reference Dataset | This regulatory science tool (RST) serves as a reference dataset summarizing the engineering characteristics for orthopedic bone fixation devices (plates and screws) in pediatric patients. | 430726 | /medical-devices/regulatory-science-tools-catalog/pediatric-plates-and-screws-used-bone-fixation-engineering-reference-dataset |
|
WearGait-PD: Wearables Dataset for Gait in Parkinson’s Disease and Age-Matched Controls | This regulatory science tool is an open-access dataset containing raw inertial measurement unit (IMU) and sensorized insole data from individuals with Parkinson’s Disease (PD) and age-matched… | 430725 | /medical-devices/regulatory-science-tools-catalog/weargait-pd-wearables-dataset-gait-parkinsons-disease-and-age-matched-controls |
|
TRUST: A Testbed Design Model for Evaluating 5G-Enabled Medical Devices | This regulatory science tool is a lab method for building a 5G network testbed to assess data transmission of medical device functions using 5G connectivity. | 430724 | /medical-devices/regulatory-science-tools-catalog/trust-testbed-design-model-evaluating-5g-enabled-medical-devices |
|
ValidPath: Whole Slide Image Processing and Machine Learning Performance Assessment Tool | This regulatory science tool is a software program written in Python for analyzing whole slide images (WSIs) and assisting developers or pathologists in the assessment of machine learning algorithms… | 430723 | /medical-devices/regulatory-science-tools-catalog/validpath-whole-slide-image-processing-and-machine-learning-performance-assessment-tool |
|
Head Mounted Display Eye-box Centering using Transverse Chromatic Aberrations | This regulatory science tool (RST) is a method for assessing the image quality of a head mounted display using the display’s transverse chromatic aberration characteristics to align the light… | 430722 | /medical-devices/regulatory-science-tools-catalog/head-mounted-display-eye-box-centering-using-transverse-chromatic-aberrations |
|
Multifunctional Method for Quantitative Evaluation of Time-Dependent Eye Hazard from Multiwavelength Laser Pointers | This regulatory science tool (RST) is a lab method for evaluating the safety of critical time-dependent radiant power, spectral, and temporal characteristics for multiwavelength high-power laser… | 430720 | /medical-devices/regulatory-science-tools-catalog/multifunctional-method-quantitative-evaluation-time-dependent-eye-hazard-multiwavelength-laser |
|
Test considerations for performing platelet and leukocyte count assays for in vitro hemocompatibility assessment of Blood-contacting materials per ASTM F2888-19 standard | This regulatory science tool is a lab method for performing platelet and leukocyte count assays per the ASTM F2888-19 standard, as a part of in vitro thrombogenicity assessment of blood-contacting… | 430721 | /medical-devices/regulatory-science-tools-catalog/test-considerations-performing-platelet-and-leukocyte-count-assays-in-vitro-hemocompatibility |
|
M-SYNTH: A Dataset for the Comparative Evaluation of Mammography AI | This regulatory science tool is a synthetic mammography dataset that includes a variety of breast densities, breast sizes, and inserted lesions imaged with different exposure levels. The dataset is… | 430719 | /medical-devices/regulatory-science-tools-catalog/m-synth-dataset-comparative-evaluation-mammography-ai |
|
Method and Phantom Design for the Evaluation of Material Quantification Accuracy of Contrast-Enhanced Spectral Computed Tomography (CT) Systems | This regulatory science tool is a method and phantom design for the evaluation of iodine-specific quantitative measurements, specifically the accurate estimation of iodine concentration within… | 430718 | /medical-devices/regulatory-science-tools-catalog/method-and-phantom-design-evaluation-material-quantification-accuracy-contrast-enhanced-spectral |
|
Highly Adaptive Risk Assessment Model (HARAM) App for Retrospective Analysis of COVID-19 Intervention Strategies | This regulatory science tool comprises a model for conducting a retrospective analysis of COVID-19 intervention strategies. | 430717 | /medical-devices/regulatory-science-tools-catalog/highly-adaptive-risk-assessment-model-haram-app-retrospective-analysis-covid-19-intervention |
|
Tissue and Blood Mimicking Materials for High Intensity Therapeutic Ultrasound | This regulatory science tool is a lab method that may be helpful while evaluating high intensity therapeutic ultrasound (HITU) devices. | 430716 | /medical-devices/regulatory-science-tools-catalog/tissue-and-blood-mimicking-materials-high-intensity-therapeutic-ultrasound |
|
Contrast Measurement Method for Optical See-Through Augmented Reality Head-Mounted Displays | This regulatory science tool (RST) describes a method to characterize digital image quality on optical see-through augmented reality head-mounted displays (AR HMDs) in ambient lighting conditions.… | 430715 | /medical-devices/regulatory-science-tools-catalog/contrast-measurement-method-optical-see-through-augmented-reality-head-mounted-displays |
|
Extended Human Action Potential Model for Heart Failure | This regulatory science tool comprises a computer model of a human action potential, which includes the effects of heart failure (HF) and the anti-arrhythmic drugs amiodarone (AM) and d-sotalol (DS). | 430714 | /medical-devices/regulatory-science-tools-catalog/extended-human-action-potential-model-heart-failure |
|
A Mock Circulation Flow Loop for Non-clinical Characterization of Pressure-Based Cardiac Output Monitoring Systems | This regulatory science tool is a lab method in the form of a physical mock circulation loop (MCL) used for simulating peripheral radial pressure waveforms. | 430712 | /medical-devices/regulatory-science-tools-catalog/mock-circulation-flow-loop-non-clinical-characterization-pressure-based-cardiac-output-monitoring |
|
Mock Circulatory Loop to Generate Variable Adult Heart Conditions for Evaluating Mechanical Circulatory Support Devices | This regulatory science tool is a lab method tool used for simulating target clinical use patient conditions on the bench using a mock circulatory loop in conjunction with the ISO 14708-5 standard… | 430713 | /medical-devices/regulatory-science-tools-catalog/mock-circulatory-loop-generate-variable-adult-heart-conditions-evaluating-mechanical-circulatory |
|
Extract Preparation for Chemical Characterization Studies – Liquid-liquid Extraction | This regulatory science tool is a model for establishing analyte recovery in chemical characterization studies following liquid-liquid extraction. | 430711 | /medical-devices/regulatory-science-tools-catalog/extract-preparation-chemical-characterization-studies-liquid-liquid-extraction |
|
BoneJ Headless: An Automated Python Tool for Bone Microstructure Analysis | This regulatory science tool is a lab method that computes bone microstructure metrics to characterize bone morphology and skeletal geometry. | 430710 | /medical-devices/regulatory-science-tools-catalog/bonej-headless-automated-python-tool-bone-microstructure-analysis |
|
Line Spread Measurement Method on Head-Mounted Displays | This regulatory science tool is a method for measuring the line spread function (LSF) and calculating the modulation transfer function (MTF) for head mounted displays (HMDs). | 430709 | /medical-devices/regulatory-science-tools-catalog/line-spread-measurement-method-head-mounted-displays |
|
Radially Variant Contrast Measurement Method on VR Head-mounted Displays | This regulatory science tool presents a method to measure the radially variant contrast on virtual reality head-mounted displays (VR HMDs) using circular concentric ring patterns, which can be… | 430708 | /medical-devices/regulatory-science-tools-catalog/radially-variant-contrast-measurement-method-vr-head-mounted-displays |
|
MIC-MET Tree: Decision Tree for Medical Imaging AI/ML Classification Metrics | This regulatory science tool presents a method (web-based decision tree) that may help developers select appropriate metric and endpoint for Artificial Intelligence (AI) / Machine learning (ML)… | 430707 | /medical-devices/regulatory-science-tools-catalog/mic-met-tree-decision-tree-medical-imaging-aiml-classification-metrics |
|
Validation Framework for Epidemiological Models | This regulatory science tool presents Python-based software for evaluating computer models that predict the number of COVID-19 deaths or hospitalizations expected in a specific locality. | 430706 | /medical-devices/regulatory-science-tools-catalog/validation-framework-epidemiological-models |
|
Open-Access Wearables Dataset to Evaluate Factors Impacting Accuracy of Smartphone Gait Metrics | This regulatory science tool presents an open-access dataset tool for the assessment of wearable technology deriving gait parameters. | 430705 | /medical-devices/regulatory-science-tools-catalog/open-access-wearables-dataset-evaluate-factors-impacting-accuracy-smartphone-gait-metrics |
|
Photoacoustic Imaging Phantoms for Assessing Image Quality and Oximetry Performance | This regulatory science tool presents a set of tissue-mimicking phantoms suitable for benchtop performance assessment of photoacoustic imaging (PAI) devices. | 430704 | /medical-devices/regulatory-science-tools-catalog/photoacoustic-imaging-phantoms-assessing-image-quality-and-oximetry-performance |
|
TSL/EED/MOS (TEEM) Calculator | This regulatory science tool is a method that applies the ISO 10993-17 toxicological risk assessment approach to medical device extractables screening data to assess systemic toxicity, genotoxicity,… | 430702 | /medical-devices/regulatory-science-tools-catalog/tsleedmos-teem-calculator |
|
Workflow for Assessing the Credibility of Patient-Specific Modeling in Medical Device Software | This regulatory science tool presents a method for assessing credibility of patient-specific computational models implemented in medical device software. | 430703 | /medical-devices/regulatory-science-tools-catalog/workflow-assessing-credibility-patient-specific-modeling-medical-device-software |
|
Chemicals List for Analytical Performance (CLAP) | Chemicals List for Analytical Performance (CLAP) | 430701 | /medical-devices/regulatory-science-tools-catalog/chemicals-list-analytical-performance-clap |
|
Benchmark Validation Dataset for Laminar Flow in an Anatomical Vascular Model of the Inferior Vena Cava | This tool provides a benchmark validation data set for laminar flow in an anatomical vascular model of the inferior vena cava (IVC). | 430700 | /medical-devices/regulatory-science-tools-catalog/benchmark-validation-dataset-laminar-flow-anatomical-vascular-model-inferior-vena-cava |
|
EEG based Machine or Deep Learning Algorithms for TBI & Stroke Classification (EMATS) | This RST contains a set of machine or deep learning algorithms which can be utilized in the development of relevant medical devices to assist in the prediction of traumatic brain injury (TBI) and… | 430699 | /medical-devices/regulatory-science-tools-catalog/eeg-based-machine-or-deep-learning-algorithms-tbi-stroke-classification-emats |
|
3D Human Induced Pluripotent Stem Cell-Derived Cardiomyocyte Cardiac Contractility Modulation Tool: 3D hiPSC-CM CCM Tool | The 3D human induced pluripotent stem cell-derived cardiomyocyte (hiPSC-CM) Cardiac Contractility Modulation (CCM) Tool, 3D hiPSC-CM CCM Tool, is a laboratory method that includes detailed… | 430698 | /medical-devices/regulatory-science-tools-catalog/3d-human-induced-pluripotent-stem-cell-derived-cardiomyocyte-cardiac-contractility-modulation-tool |
|
A "Threshold-based" Approach to Determining an Acceptance Criterion for Computational Model Validation | This RST, a “threshold-based” validation method, provides a means to determine an acceptance criterion for computational models. A “credible” computational model has the potential to provide a… | 430696 | /medical-devices/regulatory-science-tools-catalog/threshold-based-approach-determining-acceptance-criterion-computational-model-validation |
|
Mock Circulatory Loop Generated Database for Dynamic Characterization of Pressure-based Cardiac Output Monitoring Systems | This RST is a database tool consisting of nine mock circulation loop (MCL)-generated datasets for characterizing three dynamic attributes of pressure-based cardiac output monitoring systems that… | 430697 | /medical-devices/regulatory-science-tools-catalog/mock-circulatory-loop-generated-database-dynamic-characterization-pressure-based-cardiac-output |
|
Device and Material Safety Evaluation Library (DAMSEL) | The DAMSEL tool is a digital collection of published information related to the safety profile of materials commonly used in the manufacture of medical devices. This interactive application allows… | 430694 | /medical-devices/regulatory-science-tools-catalog/device-and-material-safety-evaluation-library-damsel |
|
Strategy to Estimate Low to High Cycle Fatigue Transition of Nitinol for Fatigue to Fracture Test Planning | This RST outlines a strategy for estimating the presence of cyclic phase transformation to aid in the determination of appropriate load levels for Fatigue to Fracture testing of nitinol components.… | 430695 | /medical-devices/regulatory-science-tools-catalog/strategy-estimate-low-high-cycle-fatigue-transition-nitinol-fatigue-fracture-test-planning |
|
VICTRE: In Silico Breast Imaging Pipeline | The Virtual Imaging Clinical Trials for Regulatory Evaluation (VICTRE) computer modeling pipeline is a set of tools that allow for the replication of clinical trials of in silico breast radiographic… | 430693 | /medical-devices/regulatory-science-tools-catalog/victre-silico-breast-imaging-pipeline |
|
|
Verification Test Problems for Cardiac Electrophysiology Modeling Software | A series of benchmark problems with known exact solutions that can be used to verify if tissue-level (e.g., ventricular, atrial) computational models of cardiac electrophysiology have been… | 430692 | /medical-devices/regulatory-science-tools-catalog/verification-test-problems-cardiac-electrophysiology-modeling-software |
|
The Virtual Family: A set of anatomically correct whole-body computational models | The Virtual Family provides detailed three-dimensional computational models of the human anatomy including an adult male, an adult female, and two children | 430690 | /medical-devices/regulatory-science-tools-catalog/virtual-family-set-anatomically-correct-whole-body-computational-models |
|
Toolkit for Evaluation of Head Mounted Display Image Quality | This tool allows for the creation of immersive 3D scenes using a web browser. WebXR allows for an instant deployment of any 3D scene and scripts and does not need to cater to a specific 3D engine or… | 430691 | /medical-devices/regulatory-science-tools-catalog/toolkit-evaluation-head-mounted-display-image-quality |
|
QuCAD: Software to Evaluate Wait-Time-Saving Benefits of CADt Devices | Tools that quantify wait-time-saving benefits for cases with positive diagnoses due to the adoption of Computer-Aided Triage and Notification devices in a radiology workflow | 430688 | /medical-devices/regulatory-science-tools-catalog/qucad-software-evaluate-wait-time-saving-benefits-cadt-devices |
|
Targeted Box and Blocks Test (tBBT) | A performance-based method requiring controlled grasping, transport, and release of objects that can be used to evaluate upper limb functional ability. | 430689 | /medical-devices/regulatory-science-tools-catalog/targeted-box-and-blocks-test-tbbt |
|
Performance Test Methods for Evaluation of Fluorescence Imaging Systems | Test methods that provide a practical approach for objective, quantitative evaluation/comparison of fundamental performance in near-infrared fluorescence imagers. | 430686 | /medical-devices/regulatory-science-tools-catalog/performance-test-methods-evaluation-fluorescence-imaging-systems |
|
Protocols for Characterizing Aerosol Emission from Heater Cooler Devices | A tool which may be used for measuring aerosol emission from water-based heater cooler devices with product codes DWC or DWJ. | 430687 | /medical-devices/regulatory-science-tools-catalog/protocols-characterizing-aerosol-emission-heater-cooler-devices |
|
Parsimonious Cardiac Action Potential Model of the Rabbit | Parsimonious (reduced complexity) model and software of the rabbit action potential amenable to large scale simulations of arrhythmias | 430685 | /medical-devices/regulatory-science-tools-catalog/parsimonious-cardiac-action-potential-model-rabbit |
|
Monopolar RF Thermal Dispersion Model for the Vaginal Wall | A computational modeling tool that provides first-pass estimation of the thermal effect produced in the vaginal wall by vaginal therapy devices. | 430684 | /medical-devices/regulatory-science-tools-catalog/monopolar-rf-thermal-dispersion-model-vaginal-wall |
|
Modified Dot-Blot Method to Evaluate Personal Protective Equipment (PPE) | An improved and faster method for viral challenge testing of PPE materials | 430683 | /medical-devices/regulatory-science-tools-catalog/modified-dot-blot-method-evaluate-personal-protective-equipment-ppe |
|
MIDA: A Multimodal Imaging-Based Model of the Human Head and Neck | A tool to generate computational scientific evidence as alternative approaches to clinical | 430682 | /medical-devices/regulatory-science-tools-catalog/mida-multimodal-imaging-based-model-human-head-and-neck |
|
Method of Manufactured Solutions (MMS) Code Verification source term generation tool | This study demonstrates the application of gold-standard method of manufactured solutions (MMS) code verification to verify a commercial finite element code for elastostatic solid mechanics analyses… | 430681 | /medical-devices/regulatory-science-tools-catalog/method-manufactured-solutions-mms-code-verification-source-term-generation-tool |
|
Method for Fabrication of Microcalcifications for Insertion into Phantoms used to Evaluate X-ray Breast Imaging Systems | Method to fabricate realistic microcalcification simulants with adjustable density and sizes, for insertion into phantoms used to evaluate x-ray breast imaging systems | 430680 | /medical-devices/regulatory-science-tools-catalog/method-fabrication-microcalcifications-insertion-phantoms-used-evaluate-x-ray-breast-imaging-systems |
|
Method for Estimating the Likelihood of Wireless Coexistence | A statistical approach for estimating the likelihood of wireless coexistence of a medical device in its intended environment based on experimental evaluation and realistic environment measurements | 430679 | /medical-devices/regulatory-science-tools-catalog/method-estimating-likelihood-wireless-coexistence |
|
Method for Assessing Texture Reproduction of Camera-phone-based Medical Devices | A method to assess texture reproduction of camera-phone-based medical devices with a dead leaves target | 430678 | /medical-devices/regulatory-science-tools-catalog/method-assessing-texture-reproduction-camera-phone-based-medical-devices |
|
Mechanical and Leakage Integrity Testing Protocols for Evaluating the Performance of Tissue Containment Systems Used During Power Morcellation Procedures | This tool provides protocols for conducting preclinical tests recommended in the FDA Guidance for tissue containment systems used during power morcellation procedures. | 430677 | /medical-devices/regulatory-science-tools-catalog/mechanical-and-leakage-integrity-testing-protocols-evaluating-performance-tissue-containment-systems |
|
Lumbar Integrated Fixation Devices-Best Practices for Biomechanical Evaluation Under Fatigue Loading | Recommended best practices for executing in vitro human cadaver fatigue loading and multidirectional flexibility assessment of lumbar integrated fixation device constructs. | 430675 | /medical-devices/regulatory-science-tools-catalog/lumbar-integrated-fixation-devices-best-practices-biomechanical-evaluation-under-fatigue-loading |
|
MCGPU: GPU-accelerated Monte Carlo X-ray Imaging Simulator | MC-GPU is a Monte Carlo simulation code that can generate synthetic radiographic images and computed tomography (CT) scans of realistic models of the human anatomy using fast Graphics Processing Unit… | 430676 | /medical-devices/regulatory-science-tools-catalog/mcgpu-gpu-accelerated-monte-carlo-x-ray-imaging-simulator |
|
LCD-CT: Low-contrast Detectability (LCD) Test for Assessing Advanced Nonlinear CT Image Reconstruction and Denoising Methods | Tool for assessing image quality of advanced nonlinear CT image reconstruction and denoising products, including but not limited to statistical iterative, model-based iterative, and deep learning-… | 430674 | /medical-devices/regulatory-science-tools-catalog/lcd-ct-low-contrast-detectability-lcd-test-assessing-advanced-nonlinear-ct-image-reconstruction-and |
|
Infrared Thermographs- Methods for Evaluating Laboratory Performance | Best practices for standardized performance testing of infrared thermographs intended for fever screening | 430673 | /medical-devices/regulatory-science-tools-catalog/infrared-thermographs-methods-evaluating-laboratory-performance |
|
Identifiability of Cardiac Electrophysiology Models | An approach for optimal experimental design and estimability analysis for mechanistic models of cardiac electrophysiology to determine their ‘identifiability’ | 430671 | /medical-devices/regulatory-science-tools-catalog/identifiability-cardiac-electrophysiology-models |
|
iMRMC: Software to do Multi-reader Multi-case Statistical Analysis of Reader Studies | This regulatory science tool presents a computer model to assist investigators with analyzing and sizing multi-reader multi-case (MRMC) reader studies that compare the difference in the area under… | 430672 | /medical-devices/regulatory-science-tools-catalog/imrmc-software-do-multi-reader-multi-case-statistical-analysis-reader-studies |
|
Gravity Flow Rate Testing in Enteral Tube | A Method Using 3D Printed Surrogate G-Tubes and Newtonian Analog Fluids to Compare the Flow Rates with Commercial Diets in G-Tubes with the New ISO 80369-3 Connector | 430669 | /medical-devices/regulatory-science-tools-catalog/gravity-flow-rate-testing-enteral-tube |
|
Human Shoulder Finite Element Model | A finite element model of the human shoulder for simulating humeral abduction and calculating outputs such as contact force, contact pressure, contact area, stress, and strain. | 430670 | /medical-devices/regulatory-science-tools-catalog/human-shoulder-finite-element-model |
|
Extractables Screening Protocols for Fused Filament Fabricated ABS Containing Additive-manufactured Devices | A tool to determine the extractables profile of additive-manufactured orthopedic casts produced by fused filament fabrication method | 430668 | /medical-devices/regulatory-science-tools-catalog/extractables-screening-protocols-fused-filament-fabricated-abs-containing-additive-manufactured |
|
Endoscope Geometric Distortion- A Method for Quantitative Evaluation | A mathematically easy to understand and experimentally simple method to quantitatively and objectively evaluate endoscope geometric distortion | 430667 | /medical-devices/regulatory-science-tools-catalog/endoscope-geometric-distortion-method-quantitative-evaluation |
|
Electrophysiological Biomarkers for Non-clinical Safety Evaluation of Neuro-interventional Devices | Non-clinical biomarkers of brain injury derived from epidermal and epidural electroencephalographs | 430666 | /medical-devices/regulatory-science-tools-catalog/electrophysiological-biomarkers-non-clinical-safety-evaluation-neuro-interventional-devices |
|
ECG Noise Extraction Tool (ECGNExT) | A method to estimate device-specific noise from ECG records for algorithm testing | 430665 | /medical-devices/regulatory-science-tools-catalog/ecg-noise-extraction-tool-ecgnext |
|
Digital Models of Retinal Vasculature for 3D Printed Phantoms | Digital model available on NIH's 3D Print Exchange site that can be used to fabricate tissue simulating phantoms with biomimetic vascular structures derived from a clinical image | 430664 | /medical-devices/regulatory-science-tools-catalog/digital-models-retinal-vasculature-3d-printed-phantoms |
|
Color Performance Review Tool for Endoscopy Devices | A software program written in Matlab for analyzing color performance testing data in endoscopy devices | 430663 | /medical-devices/regulatory-science-tools-catalog/color-performance-review-tool-endoscopy-devices |
|
CHemical RISk calculators (CHRIS) – Extraction Efficiency | Predicts the impact of extraction conditions, sample geometry and material properties on extraction test efficiency | 430662 | /medical-devices/regulatory-science-tools-catalog/chemical-risk-calculators-chris-extraction-efficiency |
|
CHemical RISk calculators (CHRIS) – Color Additives (v2) | CHemical RISk calculators (CHRIS) – Color Additives (v2) | 430661 | /medical-devices/regulatory-science-tools-catalog/chemical-risk-calculators-chris-color-additives-v2 |
|
CHemical RISk calculators (CHRIS) – Bulk Chemicals (v2) | Conduct screening level risk assessments to aid in the biocompatibility evaluation of bulk additives and impurities in polymeric medical device components | 430660 | /medical-devices/regulatory-science-tools-catalog/chemical-risk-calculators-chris-bulk-chemicals-v2 |
|
Cardiac Action Potential Model of the Dog | An implementation of a canine action potential model appropriate for comprehensive parameter sensitivity analysis and uncertainty quantification | 430659 | /medical-devices/regulatory-science-tools-catalog/cardiac-action-potential-model-dog |
|
Benchmark dataset for validating computational fluid dynamic (CFD) simulation of blood flow through generalized medical device geometries | A "threshold-based" validation approach that provides a well-defined acceptance criterion, which is a function of how close the simulation and experimental results are to the safety… | 430658 | /medical-devices/regulatory-science-tools-catalog/benchmark-dataset-validating-computational-fluid-dynamic-cfd-simulation-blood-flow-through |
|
An In Vitro Blood Flow Loop System for Thrombogenicity Evaluation of Medical Devices and Biomaterials | This tool provides a step-by-step protocol to design a recirculating flow loop test system and perform in vitro thrombogenicity testing of catheter-like blood-contacting medical devices and materials… | 430657 | /medical-devices/regulatory-science-tools-catalog/in-vitro-blood-flow-loop-system-thrombogenicity-evaluation-medical-devices-and-biomaterials |
|
Additively Manufactured Mock Spine Cage Designs for Mechanical Performance Test Assessments: STL Set 1 | Provides 16 mock intervertebral body fusion device (that is, a spinal cage) designs with three lattice structure implementations. Designs are provided in stereolithography (STL) file format so they… | 430656 | /medical-devices/regulatory-science-tools-catalog/additively-manufactured-mock-spine-cage-designs-mechanical-performance-test-assessments-stl-set-1 |
|
A Reusable, Compliant, Small Volume Blood Reservoir For In Vitro Hemolysis Testing | A simple and compliant fluid reservoir appropriate for in-vitro blood trauma testing. | 430655 | /medical-devices/regulatory-science-tools-catalog/reusable-compliant-small-volume-blood-reservoir-in-vitro-hemolysis-testing |
|
2D Human Induced Pluripotent Stem Cell-derived Cardiomyocyte Cardiac Contractility Modulation Tool: 2D hiPSC-CM CCM Tool | A tool to assist with evaluating and quantifying contractile response of non-excitatory electrical stimulation signals including CCM in vitro using 2D human cardiomyocyte models | 430654 | /medical-devices/regulatory-science-tools-catalog/2d-human-induced-pluripotent-stem-cell-derived-cardiomyocyte-cardiac-contractility-modulation-tool |