ENTRÉE — How to Qualify a New Approach Methodology (NAM) for Food
New Approach Methodologies (NAMs) for Food
When making regulatory decisions about the safety of chemicals found in foods, FDA’s Human Foods Program (HFP) values, among other things, 1) high-quality data; 2) a thorough, unbiased, and transparent scientific review process that considers dietary exposure; and 3) confidence in the tools and methods used to assess chemicals of interest. When it comes to new approach methodologies (NAMs), HFP evaluates the applicability, limitations, biological relevance, reliability, reproducibility, and sensitivity (collectively known as the performance standards) of each NAM to determine if it provides the information it was designed to provide, when used under the conditions for which it was intended.
Formal approaches to method validation involve lengthy and expensive processes. However, a method may not need to undergo every step of a validation process to yield valuable data depending on the method’s context of use (COU). In these instances, the process HFP uses to evaluate a NAM for regulatory use is called “qualification.” Qualification involves establishing the scientific rigor by which a NAM must be judged, based on its intended COU. Within a specific COU, qualification is HFP’s conclusion that the results of an assessment using the NAM can be relied upon to have a specific interpretation and application in product development and regulatory decision-making. Qualification also identifies the limitations of the predictive value of the NAM. Once HFP qualifies a NAM, FDA can be confident in both the predictive value of the method and its results, and it could be used by industry and other interested parties for its intended purpose.
To facilitate the development and qualification of NAMs for assessing the toxicity of chemicals and contaminants in the U.S. food supply, HFP is piloting a program called ENTRÉE (Engaging NAMs for Toxicant Regulation and Effects). The ENTRÉE pilot program provides a roadmap to qualify NAMs by delineating the data and information HFP looks for when starting a qualification evaluation. The initial focus of the pilot program is to qualify NAMs for use during post-market regulatory reviews to support chemical hazard identification, screening, risk assessment, and risk prioritization.
Below is information about the pilot program.
HFP Contact Information
All communications and questions related to the ENTRÉE pilot program should be sent to HFPNAMS@fda.hhs.gov.
Steps to Qualify a NAM Under the ENTRÉE Pilot Program
1. Initial Discussions with FDA
Test method sponsors interested in having a NAM qualified by HFP for evaluation of chemicals found in foods should contact HFP to initially discuss participation in the ENTRÉE pilot program, their test method, and the proposed COU for the method. The sponsor should be prepared to identify any data or aspect of the method they consider confidential business information not to be publicly disclosed upon completion of the qualification process. The sponsor and HFP would then discuss whether the ENTRÉE pilot program could be a good fit for the sponsor’s NAM.
2. Letter of Intent Submission
Should a test method sponsor and HFP agree that the ENTRÉE pilot program could be a good fit for the NAM, the sponsor should send a Letter of Intent to HFP providing the information listed below. HFP would then schedule a formal meeting with the sponsor to discuss the method and future steps, which may include an invitation to submit a full NAM qualification package.
a. Context of Use (COU)
Test method sponsors should define and discuss the COU proposed for their NAM. COU refers to a clearly articulated description delineating the purpose and manner of use for the NAM (i.e., when and how it will be used). Adequately specifying the context of use for a NAM is a critical initial step toward qualification of new methodologies. Models and assays should be suited for a specific purpose, and in that context, they will have different applicability, assumptions, and limitations. Importantly, it is the COU that underpins the amount of data and information HFP would look for to qualify a NAM. For example, the amount of uncertainty that is acceptable for a given NAM would depend on whether its COU has been defined for chemical screening or prioritization as compared to being defined for a more rigorous risk assessment process.
b. Biological Relevance
Test method sponsors should demonstrate that their NAM is relevant to human biology and show that it identifies, measures, or predicts an in vivo event. This may include a discussion of the toxicologically relevant mechanisms of action, concordance of NAM-generated data with in vivo or other data, how the NAM models human exposures to the chemical, and how the NAM addresses questions of biological variability.
HFP evaluates toxicity and safety assuming lifetime exposures, so the Letter of Intent should address human-relevant chronic and systemic toxicological outcomes. Sponsors should also discuss the concentrations/doses and dosing regimens that would be required when using the NAM and how these parameters model biologically relevant dietary exposures. Foods are complex biological matrices, so the ability of the NAM to evaluate chemicals in such matrices could impact the usefulness of the NAM to HFP.
Sponsors can consider using frameworks such as adverse outcome pathways or integrated approaches to testing and assessment to address the biological relevance of the NAM.
c. Technical Characterization
The test method sponsor should characterize the technical performance and other criteria of the NAM that support the stated COU. An example of how to do this is by sharing with HFP the information found below, which is based on the March 2024 Interagency Coordinating Committee on the Validation of Alternative Methods Validation Workgroup report related to characterizing a NAM. HFP reviewers can use this information to determine whether the NAM is fit for purpose within the stated COU.
Applicability domain: Describe the types of chemicals (“chemical space”) the NAM is designed to test. The chemical space is often defined by physicochemical properties or features in molecular structure. Chemicals outside of the applicability domain should be clearly delineated.
Reference chemicals: List the substances used as positive and negative test controls to verify the NAM’s functionality.
Sensitivity and specificity: Indicate the proportion of chemicals that tested positive using the NAM that were correctly classified as positive (sensitivity) and the proportion of chemicals that tested negative using the NAM that were correctly classified as negative (specificity).
Reliability: Provide data on intra- and interlaboratory reproducibility (repeated measurements obtained under different conditions such as laboratory, day, etc.) and intralaboratory repeatability (repeated measurements under identical conditions over a given time period).
Transferability: Provide interlaboratory comparisons of the accuracy and reliability of the NAM. This should include documentation of properly transferring the NAM to competent naïve laboratories, training personnel in the receiving laboratories to use the method, and the NAM producing the same results in the receiving laboratories. Such interlaboratory testing helps to identify technical issues and other factors that can be modified to improve the performance of the NAM.
Additional data and other information demonstrating the technical performance of the NAM could also be provided in the Letter of Intent to further demonstrate confidence in using the NAM to assess the safety of chemicals found in foods.
d. Data Integrity and Information Transparency
Data integrity, from acquisition through data processing and analysis, builds confidence in any NAM HFP is evaluating for qualification. To help with this, the sponsor should identify and explain the processes and procedures used to generate credible data. Additionally, the sponsor should identify which, if any, parts or processes of the NAM are intellectual property (e.g., patented). For all information deemed confidential, the sponsor should discuss how transparency of the technical rationale and biological relevance of the NAM to the scientific community and the public will be achieved. The sponsor should also provide detailed standard operating procedures for the NAM.
e. Qualification Plan
The test method sponsor should provide a qualification plan that describes the rationale for the positive and negative controls, the statistical methods employed, the sponsor’s proposed acceptance criteria, and other supporting information that demonstrates the NAM is as good or better than the current gold standard method.
f. Independent Review
The test method sponsor should discuss any independent review the NAM has received (review by scientists other than the test method developers), the process used for the review, and where the review is publicly available. For example, the method may be the subject of an Organization for Economic Co-operation and Development test guideline or a review by an international committee or body (e.g., International Liaison Group on Methods for Risk Assessment of Chemicals in Food), it may have been reviewed or used by other U.S. or international regulatory agencies, or it may have undergone robust peer review in the published literature.
g. Training Plan
Training interested parties on the purpose of a qualified NAM, when and how to use it, and how it provides improved or more human-relevant data than legacy methods can help with successful adoption and application of the NAM. Educational efforts might include presentations, videos, brochures, websites, and more. HFP encourages test method sponsors to outline plans to train stakeholders on the NAM within its COU and to send the outline to HFP along with their Letter of Intent.
Conclusion
HFP believes working with interested parties to advance the development and qualification of NAMs can help ensure the safety of our food supply and result in more predictive human-relevant models. This would allow us to reduce, refine, and replace the use of animal testing for assessing the safety of chemicals found in foods.