Safety

Ocaliva (obeticholic acid): Drug Safety Communication - Boxed Warning Added To Highlight Correct Dosing

[Posted 02/01/2018]

AUDIENCE: Pharmacy, Hepatology, Gastroenterology

ISSUE: FDA is warning that the liver disease medicine Ocaliva (obeticholic acid) has been incorrectly dosed daily instead of weekly in patients with moderate to severe primary biliary cholangitis (PBC), a rare chronic liver disease, increasing the risk of serious liver injury. To ensure correct dosing and reduce the risk of liver problems, FDA is clarifying the current recommendations for screening, dosing, monitoring, and managing PBC patients with moderate to severe liver disease taking Ocaliva. FDA is adding a new Boxed Warning, FDA’s most prominent warning, to highlight this information in the prescribing information of the drug label. FDA is also requiring a Medication Guide for patients to inform them about this issue.

As a condition of approval, FDA required the manufacturer of Ocaliva, Intercept Pharmaceuticals, to continue studying the medicine in patients with advanced PBC. These clinical trials are currently ongoing and FDA expects to receive results in 2023. FDA is adding the additional warnings to the drug label after receiving reports that Ocaliva is being given to PBC patients with moderate to severe liver impairment more often than is recommended in the prescribing information, resulting in liver decompensation, liver failure, and sometimes death. FDA will continue to monitor this medicine and will update the public if new information becomes available.

BACKGROUND: This is an update to the MedWatch safety alert for Ocaliva (obeticholic acid) - Increased Risk of Serious Liver Injury, issued 09-21-2017.

RECOMMENDATION: Health care professionals should follow the Ocaliva dosing regimen in the drug label, which is based on calculating a Child-Pugh score in PBC patients with suspected liver cirrhosis before treatment to determine their specific classification and starting dosage (see Table for the Clarified Ocaliva Dosage Regimen and more detailed instructions).  Dosing higher than recommended in the drug label can increase the risk for liver decompensation, liver failure, and sometimes death. Routinely monitor all patients for biochemical response, tolerability, and PBC progression, and re-evaluate Child-Pugh classification to determine if dosage adjustment is needed.  Close monitoring is recommended for patients at an increased risk of liver decompensation, including those with laboratory evidence of worsening liver function (e.g., total bilirubin, INR, albumin) or progression to cirrhosis.
 
Educate patients and caregivers on the symptoms of worsening liver function. Temporarily stop Ocaliva in those with laboratory or clinical evidence of worsening liver function that may indicate decompensation and monitor the patient’s liver function. If a patient’s condition returns to baseline, weigh the potential risks and benefits of restarting Ocaliva. Re-initiate, using the recommended starting dosage based on Child Pugh classification.  Consider discontinuing Ocaliva in patients who have experienced clinically significant liver-related adverse reactions.
 
Patients should be aware that your prescriber should do regular tests to check how well your liver is working while you are taking Ocaliva. If your liver problems get worse, your dose may need to be changed or stopped.  Report new or worsening severe skin itching to your health care professional. See the Drug Safety Communication for additional information.

Healthcare professionals and patients are encouraged to report adverse events or side effects related to the use of these products to the FDA's MedWatch Safety Information and Adverse Event Reporting Program:

  • Complete and submit the report Online: www.fda.gov/MedWatch/report
  • Download form or call 1-800-332-1088 to request a reporting form, then complete and return to the address on the pre-addressed form, or submit by fax to 1-800-FDA-0178

[02/01/2018 - Drug Safety Communication - FDA] en Español

Page Last Updated: 08/14/2018
Note: If you need help accessing information in different file formats, see Instructions for Downloading Viewers and Players.
Language Assistance Available: Español | 繁體中文 | Tiếng Việt | 한국어 | Tagalog | Русский | العربية | Kreyòl Ayisyen | Français | Polski | Português | Italiano | Deutsch | 日本語 | فارسی | English