Part 1 – Advances in Patient Care
Last year the Office of Device Evaluation (ODE) approved and cleared
thousands of devices used to diagnose and treat a wide variety of medical conditions.
Below we highlight several new medical devices and devices with new indications
approved or cleared during this past fiscal year that we believe will have a
particular impact on patient care.
For a complete listing of newly approved devices, please see Part
2 – INDUSTRY INFORMATION under “Original PMA/HDE Approvals for
Fiscal Year 2002.” The Premarket Approval Application (PMA) approval website
describing recently approved devices with patient information is available at
http://www.fda.gov/cdrh/consumer/mda/index.html.
| SMALLPOX VACCINE DELIVERY
SYSTEM – The bifurcated needle has been developed specifically
as a biodefense tool for the delivery of smallpox vaccine. The bifurcated
needle is a specialized high quality two-prong needle that replaced jet
injectors that had been used in the early years for conducting vaccinations.
Its unique features make it the appropriate medical device for either large-scale
immunization campaigns or emergency response. These thin metallic rods are
approximately 50 – 70 mm long and 1 mm wide, with one end flattened
and formed into two sharp tines. The u-shaped gap between the tines of the
needle, when dipped into reconstituted smallpox vaccine, holds the vaccine
by capillary action. The needle penetrates the stratum corneum layer of
the skin and delivers a small amount of vaccine to the deep epidermis. The
General Hospital Devices Branch has cleared three 510(k)s for bifurcated
needles. |
 |
 |
TUBERCULOSIS TEST
– The QuantiFERON-TB from Cellestis Limited is the first in vitro
test to detect cell-mediated immunity to Mycobacterium tuberculosis. The
tuberculin skin test that has been used for over 50 years to detect cell-mediated
immunity to M. tuberculosis is an in vivo test, requiring a repeat
patient visit within 48-72 hours to read results. The QuantiFERON-TB assay
on the other hand does not require a repeat visit to obtain results. It
measures the release of IFN-g (gamma interferon) from lymphocytes in a whole
blood sample during an overnight incubation with mycobacterial (PPD) and
control antigens. It is indicated for testing individuals who originate
from an area where tuberculosis is prevalent, or who are at increased risk
by occupation or setting (e.g., healthcare workers, prisons, injection drug
users). The assay is also indicated for testing population groups where
the consequences of active infectious tuberculosis may be severe (military,
healthcare workers, students at some institutions). Persons with a positive
result may be at increased risk of subsequently developing active tuberculosis.
|
| GLUCOSE MONITORING WRIST
WATCH FOR USE IN CHILDREN – The GlucoWatch G2 Biographer
from Cygnus, Inc., is the first glucose monitoring device that doesn't puncture
the skin that can be used by children, ages 7 and up, as well as adults.
Diabetic children and adults wear the device like a watch where a slight
electric current pulls glucose through the skin. Glucose levels are automatically
read and recorded every 10 minutes for up to 13 hours. Alarms warn users
when high, low, or rapidly declining glucose levels occur. Readings are
stored so that users can retrieve them at any time. Patients can better
manage their diabetes because they receive information about patterns in
their glucose levels. GlucoWatch measures glucose in interstitial fluid
rather than in blood. Consequently, the GlucoWatch test results may sometime
differ significantly from finger stick results. GlucoWatch does not replace
finger stick testing. |
 |
 |
SPINAL FUSION DEVICE –
InFUSE™ Bone Graft/LT-Cage™ Lumbar Tapered Fusion Device by
Medtronic Sofamor Danek is indicated for spinal fusion procedures in skeletally
mature patients with degenerative disc disease (DDD) at one level from L4-S1.
The InFUSETM Bone Graft/Lt -Cage™ Lumbar Tapered Fusion Device is
a spinal fusion device that does not require the use of autograft, a bone
taken from the patient’s hip. DDD is defined as discogenic back pain
with degeneration of the disc confirmed by patient history, function deficit
and/or neurological deficit and radiographic studies. These DDD patients
may also have up to Grade I spondylolisthesis at the involved level. InFUSE™
Bone Graft/Lt-CAGE™ devices are to be implanted via an anterior open
or an anterior laparoscopic approach. Patients receiving the InFUSE™
Bone Graft/Lt-Cage™ Lumbar Tapered Fusion Device should have had at
least six months of nonoperative treatment prior to treatment with the InFUSE™
Bone Graft/Lt-Cage™ Device. |
The device consists of three components spilt among two parts – [part
1] a metallic tapered spinal fusion cage (known as the LT-CAGE Lumbar Tapered
Fusion Device); and [part 2] a bone graft substitute (InFUSE Bone Graft) which
consists of a genetically-engineered human cytokine (rhBMP-2) and a carrier/scaffold
for the cytokine (manufactured from bovine [cow] Type I collagen), that is placed
inside of the fusion cage. The fusion cage component maintains the spacing and
temporarily stabilizes the diseased region of the spine, while the InFUSE Bone
Graft component is used to form
bone which would permanently stabilize (fuse) this portion of the spine. The
InFUSE Bone Graft component is used instead of the patient’s own bone
(autograft bone).
HEARING AID –
The RetroX Transcutaneous Air Conduction Hearing Aid System, manufactured
by Auric Hearing Systems, Inc., is a new type of hearing aid that works
without plugging the ear canal. This hearing aid sends sound through a
tube that a doctor has inserted through soft tissue between the back of
the outer ear and the outer ear canal. It is used anytime the user wants
to improve hearing. It should not be used if there is local inflammation
or infection in the skin behind the ear or if there is injury to the ear
that would make placement of the tube impossible. |
  |
 |
NEUROLOGICAL STENT FOR ANEURYSMS –
Neuroform Microdelivery Stent by SMART Therapeutics, Inc. is intended for
use with another medical device, embolic coils to treat patients with a
certain kind of aneurysm in the brain who cannot be adequately treated by
current surgical or endovascular techniques. The device consists of a self-expanding
Nitinol mesh tube along with a microdelivery catheter. The stent is deployed
across the neck of the aneurysm and embolic coils are placed through the
struts of the stent into the aneurysm. The stent retains the embolic coils
within the aneurysm, thus diverting the blood flow. |
If left untreated or inadequately treated, wide neck aneurysms are at a high
risk of rupture, resulting in a high risk of patient morbidity and mortality.
The Neuroform™ Microdelivery Stent System is designed to address the limitations
associated with the placement of coils in wide neck aneurysms.
 |
NEUROLOGICAL STENT FOR RECURRENT
INTRACRANIAL STROKE – NEUROLINK® System by Guidant Corporation
is composed of a Stent Delivery Catheter and a Balloon Dilatation Catheter.
The NEUROLINK® System is indicated for the treatment of patients with
recurrent intracranial stroke attributable to atherosclerotic disease. The
device is a balloon expandable stainless steel mesh tube that is designed
to open up the target blood vessel and provide structural support. The device
is intended for patients who have >= 50% stenosis in the target intracranial
vessels, leading to reduced blood flow to the brain with accompanying neurological
symptoms. The Balloon Dilatation Catheter allows the physician to open up
narrowed atherosclerotic areas in the blood vessel prior to placement with
the stent. The NEUROLINK® System is the first device approved to treat
these patients. |
| TESTICULAR PROSTHESIS
– The Mentor Saline-Filled Testicular Prosthesis, manufactured by
Mentor Corporation, is an oval, silicone elastomer device that is designed
to approximate the weight, shape, and softness of the normal testicle. This
device is implanted in the scrotum in males who desire cosmetic replacement
of a missing testicle, and consists of a silicone elastomer shell with an
injection port and recessed suture tab. Although the implanted device looks
and feels like a natural testicle, it does not have any other function.
The Mentor Saline-Filled Testicular Prosthesis is manufactured in four sizes
to accommodate juvenile to adult anatomies. The device is packaged empty,
and filled with sterile saline at the time of implantation. |
 |
| NEW TYPE OF DEFIBRILLATOR
– The Contak CD CRT-D by Guidant Corporation is a new type of implantable
cardioverter defibrillator (ICD) that also has the ability to deliver cardiac
resynchronization therapy. The device, the first of its kind, can be used
to treat symptoms of advanced heart failure in certain people who already
need an ICD. The device combines an implantable cardioverter defibrillator
with cardiac resynchronization therapy (CRT). The defibrillator component
detects and treats life-threatening heart rhythms. The CRT component coordinates
the beating of the left and right ventricles of the heart so that they work
together more effectively to pump blood throughout the body. The device
is intended to treat people who already need an implantable defibrillator,
whose heart timing is off and who, despite taking heart failure medication,
have symptoms of advanced heart failure, such as fatigue, shortness of breath
and difficulty performing daily activities. |
 |
.
| EXPANDABLE INDICATION OF
DEFIBRILLATOR – A new use was approved for the Ventak automatic
implantable cardiac defibrillator by Guidant Corporation so that it can
now be used prophylactically in many people who have had a previous heart
attack and an ejection fraction <= 30%. Ejection fraction is a measure
of how efficiently the heart pumps blood. A level of 30% or less is an indication
of impaired function that puts heart attack survivors at increased risk
for sudden cardiac death. The expanded indication is based on results from
the MADIT II trial. The trial showed that use of these devices reduced total
mortality by 31% for heart attack survivors with compromised heart function.
|
 |
 |
WEARABLE DEFIBRILLATOR
- The wearable cardioverter defibrillator (WCD®) by Lifecor, Inc. is
used by adult patients 24 hours a day to monitor and treat dangerous, abnormally
fast heart rhythms. These abnormal rhythms lead to a complete absence of
heart beat (sudden cardiac arrest) and death (sudden cardiac death) if they
are not treated. The WCD is a combination of two different devices. As a
cardioverter, it uses low-energy electrical shocks to return an abnormally
fast heart beat (ventricular tachycardia, or "VT") to a normal
rhythm. As a defibrillator, it uses high-energy shocks to return a very
fast, disordered heart beat (ventricular fibrillation, or "VF")
to a normal rhythm. The Wearable Cardioverter Defibrillator (WCD) does the
same job as an implantable cardioverter defibrillator (ICD). The difference
is that the WCD is non-invasive, which means that it requires no surgery,
implantation, or entry into the body. Instead, patients wear a vest-like
garment that holds the WCD parts - a monitor, electrodes, and small "alarm
module." The WCD is fully automatic and requires no patient action
to deliver treatment - but the patient is able to prevent treatment if it
is not needed. The WCD® device is worn if a patient is at risk of sudden
cardiac arrest and an implantable defibrillator is not wanted or is not
practical. |
FDA Consumer Websites
Publicly Available Device Databases
The Center for Devices and Radiological Health (CDRH) maintains electronic
databases of devices previously approved for marketing or declared substantially
equivalent to a legally marketed device at http://www.fda.gov/cdrh/consumer/mda/index.html#databases.
These databases are available in a searchable format to the public.
Consumer Information
The Division of Small Manufacturers, International and Consumer Assistance
(DSMICA) also provides information to consumers regarding medical devices and
radiation-emitting products to enhance users’ ability to avoid risk, achieve