Safety
Recall -- Firm Press Release
FDA posts press releases and other notices of recalls and market withdrawals from the firms involved as a service to consumers, the media, and other interested parties. FDA does not endorse either the product or the company.
bioMérieux, Inc. Issues Urgent Expanded Product Recall for VITEK® 2
Piperacillin/Tazobactam Test on Gram Negative Susceptibility Cards
Contact:
Consumer:
1-800-682-2666 (option 3)
Media:
Allan Mohess
1-919-620-2937
allan.mohess@biomerieux.com
FOR IMMEDIATE RELEASE - April 8, 2011 - As a follow up to the communication issued on September 16, 2010, bioMérieux, Inc. is voluntarily expanding its worldwide product recall of VITEK® 2 Gram Negative Susceptibility Cards containing the antibiotic Piperacillin/Tazobactam (TZP
). These cards, manufactured after March 10, 2009, are used in clinical laboratories to perform antimicrobial susceptibility testing as part of the VITEK® 2 System. Clinical laboratories have been notified to perform an alternative method of testing prior to reporting results for:
- Piperacillin/Tazobactam (TZP
) and Escherichia coli, Morganella morganii, Proteus mirabilis, Proteus vulgaris, Providencia rettgeri, Providencia stuartii, Pseudomonas aeruginosa and Salmonella enterica - Piperacillin/Tazobactam (TZP
) and Klebsiella pneumoniae with resistant results
for the organisms listed above are potentially inaccurate and should not be reported. An alternative method should be used for testing and reporting Piperacillin/Tazobactam susceptibility. Customers can continue to use the VITEK® 2 Gram Negative Susceptibility cards for other antibiotics and for TZP
testing of Acinetobacter baumannii, Citrobacter koseri, Serratia marcescens and Klebsiella pneumoniae with susceptible results.
), and resistant isolates reported as susceptible to Piperacillin/Tazobactam (TZP
). The current expanded recall is based on these findings. This investigation also confirmed the previously identified performance issues with E. coli and K. pneumoniae testing.
) and isolates of these specific organisms, or for falsely-resistant K. pneumoniae results.
are affected by this product correction.Other information can be found at www.biomerieux.com.

Card Name | Ref. # |
| Card Name | Ref. # |
| Card Name | Ref. # |
AST-N080 | 22214 |
| AST-N117 | 22290 |
| AST-N152 | 22347 |
AST-N081 | 22215 |
| AST-N118 | 22291 |
| AST-N153 | 22348 |
AST-N082 | 22217 |
| AST-N120 | 22293 |
| AST-N155 | 22352 |
AST-N084 | 22224 |
| AST-N121 | 22295 |
| AST-N156 | 22353 |
AST-N085 | 22225 |
| AST-N122 | 22299 |
| AST-N157 | 22354 |
AST-N086 | 22234 |
| AST-N123 | 22301 |
| AST-N158 | 22355 |
AST-N087 | 22235 |
| AST-N124 | 22303 |
| AST-N159 | 22356 |
AST-N088 | 22236 |
| AST-N127 | 22308 |
| AST-N160 | 22357 |
AST-N089 | 22237 |
| AST-N128 | 22309 |
| AST-N161 | 410026 |
AST-N090 | 22240 |
| AST-N129 | 22310 |
| AST-N162 | 410023 |
AST-N091 | 22241 |
| AST-N130 | 22311 |
| AST-N163 | 410084 |
AST-N093 | 22243 |
| AST-N131 | 22315 |
| AST-N164 | 410101 |
AST-N093 | 22246 |
| AST-N132 | 22316 |
| AST-N165 | 410102 |
AST-N094 | 22247 |
| AST-N133 | 22318 |
| AST-N166 | 410136 |
AST-N095 | 22249 |
| AST-N134 | 22319 |
| AST-N167 | 410138 |
AST-N096 | 22250 |
| AST-N135 | 22322 |
| AST-N168 | 410139 |
AST-N097 | 22251 |
| AST-N136 | 22323 |
| AST-N170 | 410222 |
AST-N098 | 22253 |
| AST-N137 | 22324 |
| AST-N171 | 410249 |
AST-N100 | 22256 |
| AST-N138 | 22326 |
| AST-N172 | 410298 |
AST-N103 | 22259 |
| AST-N139 | 22327 |
| AST-N174 | 410404 |
AST-N104 | 22261 |
| AST-N140 | 22328 |
| AST-N175 | 410403 |
AST-N105 | 22262 |
| AST-N141 | 22329 |
| AST-N176 | 410402 |
AST-N106 | 22264 |
| AST-N142 | 22332 |
| AST-N177 | 410392 |
AST-N107 | 22265 |
| AST-N143 | 22333 |
| AST-N178 | 410393 |
AST-N108 | 22272 |
| AST-N144 | 22334 |
| AST-N179 | 410640 |
AST-N109 | 22273 |
| AST-N145 | 22338 |
| AST-N180 | 410771 |
AST-N110 | 22274 |
| AST-N146 | 22341 |
| AST-N181 | 410803 |
AST-N111 | 22275 |
| AST-N147 | 22342 |
| AST-N182 | 410804 |
AST-N112 | 22281 |
| AST-N148 | 22343 |
| AST-N183 | 411021 |
AST-N114 | 22283 |
| AST-N149 | 22344 |
| AST-N184 | 411154 |
AST-N115 | 22285 |
| AST-N150 | 22345 |
|
|
|
AST-N116 | 22289 |
| AST-N151 | 22346 |
|
|
|
| Cards Distributed Globally (including U.S.) | |
Card Name | Ref. # |
AST-GN22 | 22227 |
AST-GN23 | 22228 |
AST-GN24 | 22229 |
AST-GN25 | 22230 |
AST-GN26 | 22244 |
AST-GN27 | 22245 |
AST-GN28 | 22254 |
AST-GN29 | 22266 |
AST-GN30 | 22267 |
AST-GN31 | 22268 |
AST-GN32 | 22269 |
AST-GN33 | 22270 |
AST-GN34 | 22271 |
AST-GN35 | 22286 |
AST-GN36 | 22300 |
AST-GN37 | 22312 |
AST-GN39 | 22337 |
AST-GN40 | 410756 |
AST-GN41 | 410757 |
AST-GN42 | 410758 |
AST-GN43 | 410759 |
AST-GN44 | 410805 |
###
RSS Feed for FDA Recalls Information [what's this?]
Recalled Product Photos Are Also Available on FDA's Flickr Photostream.