Safety

Iclusig (ponatinib) tablets

Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER)

June 2016

Summary View

WARNINGS AND PRECAUTIONS

Increased Toxicity in Newly Diagnosed Chronic Phase CML
  • In a prospective randomized clinical trial in the first line treatment of newly diagnosed patients with chronic phase (CP) CML, single agent Iclusig 45 mg once-daily increased the risk of serious adverse reactions 2-fold compared to single agent imatinib 400 mg once-daily. The median exposure to treatment was less than 6 months. The trial was halted for safety in October 2013.
  • Arterial and venous thrombosis and occlusions occurred at least twice as frequently in the Iclusig arm compared to the imatinib arm. Compared to imatinib-treated patients, Iclusig-treated patients exhibited a greater incidence of myelosuppression, pancreatitis, hepatotoxicity, cardiac failure, hypertension, and skin and subcutaneous tissue disorders. Iclusig is not indicated and is not recommended for the treatment of patients with newly diagnosed CP-CML.

ADVERSE REACTIONS

(addition to bulleted list)

  • Increased Toxicity in Newly Diagnosed Chronic Phase CML

(addition of subheadings)

  • Clinical Trial Experience
  • Previously Treated CML or Ph+ ALL
  • The adverse reactions described in this section were identified in a single-arm, open-label, international, multicenter trial in 449 patients with CML or Ph+ ALL whose disease was considered to be resistant or intolerant to prior tyrosine kinase inhibitor (TKI) therapy including those with the BCR-ABL T315I mutation…

MEDICATION GUIDE

What is Iclusig?

  • Iclusig is not for use to treat people with newly diagnosed chronic phase CML.

 

December 2015

Summary View

WARNINGS AND PRECAUTIONS

Vascular Occlusion
  • Updates in graph
Arterial Occlusion and Thrombosis
  • Renal artery stenosis, associated with worsening, labile or treatment-resistant hypertension, has occurred in some Iclusig-treated patients
Hypertension
  • In the event of significant worsening, labile or treatment-resistant hypertension, interrupt treatment and consider evaluating for renal artery stenosis.

 

December 2013

Summary View

BOXED WARNING

WARNING: VASCULAR OCCLUSION, HEART FAILURE, and HEPATOTOXICITY

Vascular Occlusion:
  • Arterial and venous thrombosis and occlusions have occurred in at least 27% of Iclusig treated patients, including fatal myocardial infarction, stroke, stenosis of large arterial vessels of the brain, severe peripheral vascular disease, and the need for urgent revascularization procedures. Patients with and without cardiovascular risk factors, including patients age 50 years or younger, experienced these events
  • Monitor for evidence of thromboembolism and vascular occlusion. Interrupt or stop Iclusig immediately for vascular occlusion. A benefit risk consideration should guide a decision to restart Iclusig therapy

WARNINGS AND PRECAUTIONS

Vascular Occlusion
  • Arterial and venous thrombosis and occlusions, including fatal myocardial infarction, stroke, stenosis of large arterial vessels of the brain, severe peripheral vascular disease, and the need for urgent revascularization procedures have occurred in at least 27% of Iclusig-treated patients from the phase 1 and phase 2 trials. Iclusig can cause fatal and life-threatening vascular occlusion within 2 weeks of starting treatment. Iclusig can also cause recurrent or multi-site vascular occlusion …
Heart Failure
  • Fatal and serious heart failure or left ventricular dysfunction occurred in 5% of Iclusig-treated patients (N =22). Eight percent of patients (N= 35) experienced any grade of heart failure or left ventricular dysfunction. Monitor patients for signs or symptoms consistent with heart failure and treat as clinically indicated, including interruption of Iclusig. Consider discontinuation of Iclusig in patients who develop serious heart failure
Hypertension
  • Treatment-emergent hypertension occurred in 67% of patients (300/449). Eight patients (2%) treated with Iclusig in clinical trials experienced treatment-emergent symptomatic hypertension as a serious adverse reaction, including hypertensive crisis. Patients may require urgent clinical intervention for hypertension associated with confusion, headache, chest pain, or shortness of breath
Neuropathy
  • Peripheral and cranial neuropathy have occurred in Iclusig-treated patients. Overall, 13% (59/449) of Iclusig-treated patients experienced a peripheral neuropathy event of any grade (2%, grade 3/4). In clinical trials, the most common peripheral neuropathies reported were peripheral neuropathy (4%, 18/449), paresthesia (4%, 17/449), hypoesthesia (2%, 11/449), and hyperesthesia (1%, 5/449). Cranial neuropathy developed in 1% (6/449) of Iclusig-treated patients (<1% grade 3/4).
Ocular Toxicity
  • Serious ocular toxicities leading to blindness or blurred vision have occurred in Iclusig-treated patients. Retinal toxicities including macular edema, retinal vein occlusion, and retinal hemorrhage occurred in 3% of Iclusig-treated patients. Conjunctival or corneal irritation, dry eye, or eye pain occurred in 13% of patients. Visual blurring occurred in 6% of the patients. Other ocular toxicities include cataracts, glaucoma, iritis, iridocyclitis, and ulcerative keratitis. Conduct comprehensive eye exams at baseline and periodically during treatment

 

Page Last Updated: 07/07/2016
Note: If you need help accessing information in different file formats, see Instructions for Downloading Viewers and Players.
Language Assistance Available: Español | 繁體中文 | Tiếng Việt | 한국어 | Tagalog | Русский | العربية | Kreyòl Ayisyen | Français | Polski | Português | Italiano | Deutsch | 日本語 | فارسی | English