Safety

Depakene (valproic acid) Capsules and Oral Solution, Depakote (divalproex sodium) Delayed Release and Depakote ER (Extended Release) Tablets, Depakote Sprinkle Capsules (divalproex sodium coated particles in capsules), Depacon (valproate sodium) Injection

Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER)

February 2016

Summary View

ADVERSE REACTIONS

Postmarketing
  • Dermatologic: nail and nail bed disorders
  • Metabolism and nutrition: weight gain

DRUG INTERACTIONS

  • Effects of Co-Administered Drugs on Valproate Clearance: addition of cholestyramine (in the prescribing information for Depakene [valproic acid] capsules and oral solution only)
  • Effects of Valproate on Other Drugs: rufinamide

 

September 2015

Summary View

ADVERSE REACTIONS

Post-Marketing Experience
  • …Reproductive: Aspermia, azoospermia, decreased sperm count, decreased spermatozoa motility,

male infertility, and abnormal spermatozoa morphology.

 

March 2015

Summary View

ADVERSE REACTIONS

Post-Marketing Experience
  • Dermatologic: addition of hair texture changes and hair color changes
  • Endocrine: addition of hyperandrogenism, hirsutism, and elevated testosterone level

 

January 2015

Summary View

WARNINGS AND PRECAUTIONS

Birth defects
  • Pregnancy registry data show that maternal valproate use can cause neural tube defects and other structural abnormalities(e.g., craniofacial defects, cardiovascular malformations, hypospadias, limb malformations).
Bleeding and other hematopoietic disorders
  • Valproate is associated with dose-related thrombocytopenia… Valproate use has also been associated with decreases in other cell lines and myelodysplasia… Because of reports of cytopenias, inhibition of the secondary phase of platelet aggregation, and abnormal coagulation parameters, (e.g., low fibrinogen, coagulation factor deficiencies, acquired von Willebrand’s disease), measurements of complete blood counts and coagulation tests are recommended before initiating therapy and at periodic intervals.
Drug Reaction with Eosinophilia and Systemic Symptoms (DRESS)/Multiorgan hypersensitivity reaction
  • Drug Reaction with Eosinophilia and Systemic Symptoms (DRESS), also known as Multiorgan Hypersensitivity, has been reported in patients taking valproate. DRESS may be fatal or lifethreatening. DRESS typically, although not exclusively, presents with fever, rash, and/or lymphadenopathy, in association with other organ system involvement, such as hepatitis,nephritis, hematological abnormalities, myocarditis, or myositis sometimes resembling an acute viral infection. Eosinophilia is often present. Because this disorder is variable in its expression, other organ systems not noted here may be involved. It is important to note that early manifestations of hypersensitivity, such as fever or lymphadenopathy, may be present even though rash is not evident. If such signs or symptoms are present, the patient should be evaluated immediately. Valproate should be discontinued and not be resumed if an alternative etiology for the signs or symptoms cannot be established.
     

 

 June 2014

Summary View

ADVERSE REACTIONS
 

Post-Marketing Experience
 
  • Musculoskeletal: Fractures, decreased bone mineral density, osteopenia, osteoporosis

July 2013

Summary View

BOXED WARNING

Hepatotoxicity
  • Patients with Mitochondrial Disease: There is an increased risk of valproate-induced acute liver failure and resultant deaths in patients with hereditary neurometabolic syndromes caused by DNA mutations of the mitochondrial DNA Polymerase γ (POLG) gene (e.g. Alpers Huttenlocher Syndrome). Valproate is contraindicated in patients known to have mitochondrial disorders caused by POLG mutations and children under two years of age who are clinically suspected of having a mitochondrial disorder [see Contraindications (4)]. In patients over two years of age who are clinically suspected of having a hereditary mitochondrial disease, ...

CONTRAINDICATIONS

  • Valproate is contraindicated in patients known to have mitochondrial disorders caused by mutations in mitochondrial DNA polymerase γ (POLG; e.g., Alpers-Huttenlocher Syndrome) and children under two years of age who are suspected of having a POLG-related disorder

WARNINGS AND PRECAUTIONS

Hepatotoxicity

Patients with Known or Suspected Mitochondrial Disease

  • Valproate is contraindicated in patients known to have mitochondrial disorders caused by POLG mutations and children under two years of age who are clinically suspected of having a mitochondrial disorder [see Contraindications (4)]. Valproate-induced acute liver failure and liver-related deaths have been reported in patients with hereditary neurometabolic syndromes caused by mutations in the gene for mitochondrial DNA polymerase γ (POLG) (e.g., Alpers-Huttenlocher Syndrome) at a higher rate than those without these syndromes. Most of the reported cases of liver failure in patients with these syndromes have been identified in children and adolescents...

 

June 2013

Summary View

BOXED WARNING

Fetal Risk
  • Valproate can cause major congenital malformations, particularly neural tube defects (e.g., spina bifida). In addition, valproate can cause decreased IQ scores following in utero exposure. Valproate is therefore contraindicated in pregnant women treated for prophylaxis of migraine. Valproate should only be used to treat pregnant women with epilepsy or bipolar disorder if other medications have failed to control their symptoms or are otherwise unacceptable.
 

WARNINGS AND PRECAUTIONS

Birth Defects
  • Valproate can cause fetal harm when administered to a pregnant woman. Pregnancy registry data show that maternal valproate use can cause neural tube defects and other structural abnormalities (e.g., craniofacial defects, cardiovascular malformations and malformations involving various body systems). The rate of congenital malformations among babies born to mothers using valproate is about four times higher than the rate among babies born to epileptic mothers using other anti-seizure monotherapies. Evidence suggests that folic acid supplementation prior to conception and during the first trimester of pregnancy decreases the risk for congenital neural tube defects in the general population.
Decreased IQ Following in utero Exposure
  • Valproate can cause decreased IQ scores following in utero exposure. Published epidemiological studies have indicated that children exposed to valproate in utero have lower cognitive test scores than children exposed in utero to either another antiepileptic drug or to no antiepileptic drugs. The largest of these studies1 is a prospective cohort study conducted in the United States and United Kingdom that found that children with prenatal exposure to valproate (n=62) had lower IQ scores at age 6 (97 [95% C.I. 94-101]) than children with prenatal exposure to the other antiepileptic drug monotherapy treatments evaluated: lamotrigine (108 [95% C.I. 105–110]), carbamazepine (105 [95% C.I. 102–108]), and phenytoin (108 [95% C.I. 104–112]). It is not known when during pregnancy cognitive effects in valproate-exposed children occur. Because the women in this study were exposed to antiepileptic drugs throughout pregnancy, whether the risk for decreased IQ was related to a particular time period during pregnancy could not be assessed.
  • Although all of the available studies have methodological limitations, the weight of the evidence supports the conclusion that valproate exposure in utero can cause decreased IQ in children.
  • In animal studies, offspring with prenatal exposure to valproate had malformations similar to those seen in humans and demonstrated neurobehavioral deficits.
Use in Women of Childbearing Potential
  • ...It is not known whether the risk of neural tube defects or decreased IQ in the offspring of women receiving valproate is reduced by folic acid supplementation. Dietary folic acid supplementation both prior to conception and during pregnancy should be routinely recommended for patients using valproate.
 

USE IN SPECIFIC POPULATIONS

Pregnancy
  • Fetal Risk Summary: In animal studies, offspring with prenatal exposure to valproate had structural malformations similar to those seen in humans and demonstrated neurobehavioral deficits.
 
Clinical Considerations
  • Valproate can cause decreased IQ scores in children whose mothers were treated with valproate during pregnancy.
  • Because of the risks of decreased IQ, neural tube defects, and other fetal adverse events, which may occur very early in pregnancy:
  • Valproate should not be administered to a woman of childbearing potential unless the drug is essential to the management of her medical condition. This is especially important when valproate use is considered for a condition not usually associated with permanent injury or death (e.g., migraine).
  • Valproate should not be used to treat women with epilepsy who are pregnant or who plan to become pregnant unless other treatments have failed to provide adequate symptom control or are otherwise unacceptable. In such women, the benefits of treatment with valproate during pregnancy may still outweigh the risks. When treating a pregnant woman or a woman of childbearing potential, carefully consider both the potential risks and benefits of treatment and provide appropriate counseling.

 

Page Last Updated: 03/14/2016
Note: If you need help accessing information in different file formats, see Instructions for Downloading Viewers and Players.
Language Assistance Available: Español | 繁體中文 | Tiếng Việt | 한국어 | Tagalog | Русский | العربية | Kreyòl Ayisyen | Français | Polski | Português | Italiano | Deutsch | 日本語 | فارسی | English