Safety

Victoza (Liraglutide [rDNA orgin]) Injection

Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER)

April 2016

Summary View

ADVERSE REACTIONS

  • Inclusion of results from Trial NN2211-3916, which was a 26-week double-blind placebo-controlled, randomized, multicenter, multinational, parallel-group trial which assessed the safety and efficacy of liraglutide in subjects with type 2 diabetes and moderate renal impairment.

 

March 2015

Summary View

BOXED WARNING (edited)

WARNING: RISK OF THYROID C-CELL TUMORS

  • Liraglutide causes dose-dependent and treatment-duration-dependent thyroid C-cell tumors at clinically relevant exposures in both genders of rats and mice. It is unknown whether Victoza causes thyroid C-cell tumors, including medullary thyroid carcinoma (MTC), in humans, as the human relevance of liraglutide-induced rodent thyroid C-cell tumors has not been determined [see Warnings and Precautions (5.1) and Nonclinical Toxicology (13.1)].
  • Victoza is contraindicated in patients with a personal or family history of MTC and in patients with Multiple Endocrine Neoplasia syndrome type 2 (MEN 2). Counsel patients regarding the potential risk for MTC with the use of Victoza and inform them of symptoms of thyroid tumors (e.g. a mass in the neck, dysphagia, dyspnea, persistent hoarseness). Routine monitoring of serum calcitonin or using thyroid ultrasound is of uncertain value for early detection of MTC in patients treated with Victoza [see Contraindications (4), Warnings and Precautions (5.1)].

WARNINGS AND PRECAUTIONS

Risk of Thyroid C-cell Tumors section edited
  • Liraglutide causes dose-dependent and treatment-duration-dependent thyroid C-cell tumors (adenomas and/or carcinomas) at clinically relevant exposures in both genders of rats and mice [see Nonclinical Toxicology (13.1)]. Malignant thyroid C-cell carcinomas were detected in rats and mice. It is unknown whether Victoza will cause thyroid C-cell tumors, including medullary thyroid carcinoma (MTC), in humans, as the human relevance of liraglutide-induced rodent thyroid C-cell tumors has not been determined.
  • Cases of MTC in patients treated with Victoza have been reported in the postmarketing period; the data in these reports are insufficient to establish or exclude a causal relationship between MTC and Victoza use in humans.
  • Victoza is contraindicated in patients with a personal or family history of MTC or in patients with MEN 2. Counsel patients regarding the potential risk for MTC with the use of Victoza and inform them of symptoms of thyroid tumors (e.g. a mass in the neck, dysphagia, dyspnea, persistent hoarseness).
  • Routine monitoring of serum calcitonin or using thyroid ultrasound is of uncertain value for early detection of MTC in patients treated with Victoza. Such monitoring may increase the risk of unnecessary procedures, due to low test specificity for serum calcitonin and a high background incidence of thyroid disease. Significantly elevated serum calcitonin may indicate MTC and patients with MTC usually have calcitonin values >50 ng/L. If serum calcitonin is measured and found to be elevated, the patient should be further evaluated. Patients with thyroid nodules noted on physical examination or neck imaging should also be further evaluated.

 

April 2013

Summary View 

WARNINGS AND PRECAUTIONS

Pancreatitis
  • Based on spontaneous postmarketing reports, acute pancreatitis, including fatal and non-fatal hemorrhagic or necrotizing pancreatitis, has been observed in patients treated with Victoza.

 

Page Last Updated: 05/13/2016