Tracleer (Bosentan) Tablets

Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER) – October 2012

Summary View

 

WARNINGS AND PRECAUTIONS

Patients with Pre-existing Hepatic Impairment
  • Tracleer is not recommended in patients with moderate or severe liver impairment. In addition, initiation of Tracleer should generally be avoided in patients with elevated aminotransferases (> 3 x ULN) prior to drug initiation because monitoring hepatotoxicity in these patients may be more difficult.
 

USE IN SPECIFIC POPULATIONS

  • Because there is in vitro and in vivo evidence that the main route of excretion of bosentan is biliary, liver impairment could be expected to increase exposure (Cmax and AUC) of bosentan. The pharmacokinetics of Tracleer has not been evaluated in patients with severe liver impairment (Child-Pugh Class C). In patients with moderate hepatic impairment (Child-Pugh Class B), the systemic exposures to bosentan and its active metabolite increased significantly. Tracleer should generally be avoided in patients with moderate or severe liver impairment. Pharmacokinetics of bosentan was not altered in patients with mild impairment of hepatic function (Child-Pugh Class A).

 

-
-