Safety
-
Dantrium (dantrolene sodium) Oral Capsule
Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER) – July 2012
BOXED WARNING
- Spontaneous reports suggest a higher proportion of hepatic events with fatal outcome in elderly patients receiving Dantrium. However, the majority of these cases were complicated with confounding factors such as intercurrent illnesses and/or concomitantpotentially hepatotoxic medications.
WARNINGS
Geriatric Use
- Clinical studies of Dantrium did not include sufficient numbers of subjects aged 65 and over to determine whether they respond differently from younger subjects. Other reported clinical experience in the literature has not identified differences in responses between the elderly and younger patients. In general, dose selection for an elderly patient should be cautious, reflecting the greater frequency of decreased hepatic, renal, or cardiac function, and of concomitant disease or other drug therapy. As with all patients receiving Dantrium, it is recommended that elderly patients receive the lowest dose compatible with the optimal response. Spontaneous reports suggest a higher proportion of hepatic events with fatal outcome in elderly patients receiving Dantrium. However, the majority of these cases were complicated with confounding factors such as intercurrent illnesses and/or concomitant potentially hepatotoxic medications.
Drug Interactions
- Drowsiness may occur with Dantrium therapy, and the concomitant administration of CNS depressants such as sedatives and tranquilizing agents may result in further drowsiness. Cardiovascular collapse in patients treated simultaneously with verapamil and dantrolene sodium is rare. Administration of Dantrium may potentiate vecuronium-induced neuromuscular block.
PRECAUTIONS
- Dantrium should be used with caution in patients with impaired pulmonary function, particularly those with obstructive pulmonary disease, and in patients with severely impaired cardiac function due to myocardial disease. Dantrium is associated with pleural effusion with associated eosinophilia. It should be used with caution in patients with a history of previous liver disease or dysfunction.
ADVERSE REACTIONS
Gastrointestinal
- Constipation rarely progressing to signs of intestinal obstruction, ...nausea and/or vomiting.
Neurologic
- Drooling
Cardiovascular
- heart failure
Hematologic
- Aplastic anemia, anemia, leukopenia, lymphocytic lymphoma, thrombocytopenia
Respiratory
- respiratory depression
Hypersensitivity
- pleural effusion with associated eosinophilia
The published literature has included some reports of Dantrium use in patients with Neuroleptic Malignant Syndrome (NMS). Dantrium capsules are not indicated for the treatment of NMS and patients may expire despite treatment with Dantrium capsules
-
-







