Ceftriaxone for Injection and Dextrose Injection in Duplex Container

Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER) – January 2012

 

Summary View

CONTRAINDICATIONS

Neonates (≤28 days)
  • Ceftriaxone for Injection and Dextrose Injection is contraindicated in neonates if they require (or are expected to require) treatment with calcium-containing IV solutions, including continuous calcium-containing infusions such as parenteral nutrition because of the risk of precipitation of ceftriaxone-calcium (see CLINICAL PHARMACOLOGY, WARNINGS and DOSAGE AND ADMINISTRATION). 
  • A small number of cases of fatal outcomes in which a crystalline material was observed in the lungs and kidneys at autopsy have been reported in neonates receiving Ceftriaxone ..... At least one fatality has been reported in a neonate in whom Ceftriaxone for Injection and Dextrose Injection and calcium-containing fluids were administered at different time points via different intravenous lines; no crystalline material was observed at autopsy in this neonate. There have been no similar reports in patients other than neonates. 
     

WARNINGS

Interaction with Calcium-Containing Products 
  • Precipitation of ceftriaxone-calcium can occur when Ceftriaxone for Injection and Dextrose Injection is mixed with calcium-containing solutions in the same IV administration line. Ceftriaxone for Injection and Dextrose Injection must not be administered simultaneously with calcium-containing IV solutions, including continuous calcium-containing infusions such as parenteral nutrition via a Y-site. However, in patients other than neonates, ..... (see CLINICAL PHARMACOLOGY, CONTRAINDICATIONS and DOSAGE AND ADMINISTRATION). 
Hemolytic Anemia
 
  • An immune mediated hemolytic anemia has been observed in patients receiving cephalosporin class antibacterials including Ceftriaxone for Injection and Dextrose Injection. Severe cases of hemolytic anemia, including fatalities, have been reported during treatment in both adults and children. If a patient develops anemia...... 

ADVERSE REACTIONS

Postmarketing Experience
  • A small number of cases of fatal outcomes in which a crystalline material was observed in the lungs and kidneys at autopsy have been reported in neonates receiving Ceftriaxone......

 

 
-