Flolan (epoprostenol sodium) injection

Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER) – March 2011

 

Summary View

 

ADVERSE REACTIONS

Adverse Events During Chronic Administration
  • Interpretation of adverse events is complicated by the clinical features of PAH, which are similar to some of the pharmacologic effects of FLOLAN (e.g., dizziness, syncope). Adverse events which may be related to the underlying disease include dyspnea, fatigue, chest pain, edema, hypoxia, right ventricular failure, and pallor. Several adverse events, on the other hand, can clearly be attributed to FLOLAN. These include hypotension, bradycardia, tachycardia, pulmonary edema, bleeding at various sites, thrombocytopenia, headache, abdominal pain, pain (unspecified), sweating, rash, arthralgia, jaw pain, flushing, diarrhea, nausea and vomiting, flu-like symptoms, anxiety/nervousness, and agitation. In addition, chest pain, fatigue, and pallor have been reported during FLOLAN therapy, and a role for the drug in these events cannot be excluded.
Adverse Events Attributable to the Drug Delivery System
  • During controlled PAH trials of up to 12 weeks’ duration, the local infection rate was about 18%, and the rate for pain was about 11%. During long-term follow-up, sepsis was reported at a rate of 0.3 infections/patient per year in patients treated with FLOLAN.
-
-