• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Safety

  • Print
  • Share
  • E-mail

Toviaz (fesoterodine fumarate) extended release tablets

Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER)

 

December 2011 

Summary View 

ADVERSE REACTIONS

Post-marketing Experience
  • Skin and subcutaneous tissue disorders: pruritis and urticaria

 

November 2011

Summary View

WARNINGS AND PRECAUTIONS

Concomitant Administration with CYP3A4 Inhibitors subsection
  • No dosing adjustments are recommended in the presence of moderate CYP3A4 inhibitors (e.g., erythromycin, fluconazole, diltiazem, verapamil and grapefruit juice).  While the effect of weak CYP3A4 inhibitors (e.g. cimetidine) was not examined by clinical study, some pharmacokinetic interaction is expected, albeit less than that observed with moderate CYP3A4 inhibitors
Drug Interactions
CYP3A4 Inhibitors
  • There is no clinically relevant effect of moderate CYP3A4 inhibitors on the pharmacokinetics of fesoterodine. Following blockade of CYP3A4 by coadministration of the moderate CYP3A4 inhibitor fluconazole 200 mg twice a day for 2 days, the average (90% confidence interval) increase in Cmax and AUC of the active metabolite of fesoterodine was approximately 19% (11% - 28%) and 27% (18% - 36%) respectively. No dosing adjustments are recommended in the presence of moderate CYP3A4 inhibitors (e.g., erythromycin, fluconazole, diltiazem, verapamil and grapefruit juice). The effect of weak CYP3A4 inhibitors (e.g. cimetidine) was not examined; it is not expected to be in excess of the effect of moderate inhibitors.
Warfarin
  • A clinical study has shown that fesoterodine 8 mg once daily has no significant effect on the pharmacokinetics or the anticoagulant activity (PT/INR) of warfarin 25 mg. Standard therapeutic monitoring for warfarin should be continued.

 

February 2011

Summary View

CONTRAINDICATIONS

  • ...Toviaz is also contraindicated in patients with known hypersensitivity...to tolterodine tartrate tablets or tolterodine tartrate extended-release capsules.

WARNINGS AND PRECAUTIONS

  • Angioedema of the face, lips, tongue, and/or larynx has been reported with fesoterodine. In some cases angioedema occurred after the first dose. Angioedema associated with upper airway swelling may be life-threatening. If involvement of the tongue, hypopharynx, or larynx occurs, fesoterodine should be promptly discontinued and appropriate therapy and/or measures to ensure a patent airway should be promptly provided.

 

-
-