Safety
Uloric (febuxostat tablets)
Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER)
November 2012
WARNINGS AND PRECAUTIONS
Hepatic Effects
There have been postmarketing reports of fatal and non-fatal hepatic failure in patients taking ULORIC, although the reports contain insufficient information necessary to establish the probable cause. During randomized controlled studies, transaminase elevations greater than three times the upper limit of normal (ULN) were observed (AST: 2%, 2%, and ALT: 3%, 2% in ULORIC and allopurinol-treated patients, respectively). No dose-effect relationship for these transaminase elevations was noted. Obtain a liver test panel (serum alanine aminotransferase [ALT], aspartate aminotransferase [AST], alkaline phosphatase, and total bilirubin) as a baseline before initiating ULORIC.
Measure liver tests promptly in patients who report symptoms that may indicate liver injury, including fatigue, anorexia, right upper abdominal discomfort, dark urine or jaundice. In this clinical context, if the patient is found to have abnormal liver tests (ALT greater than three times the upper limit of the reference range), ULORIC treatment should be interrupted and investigation done to establish the probable cause. ULORIC should not be restarted in these patients without another explanation for the liver test abnormalities.
Patients who have serum ALT greater than three times the reference range with serum total bilirubin greater than two times the reference range without alternative etiologies are at risk for severe druginduced liver injury and should not be restarted on ULORIC. For patients with lesser elevations of serum ALT or bilirubin and with an alternate probable cause, treatment with ULORIC can be used with caution.
ADVERSE REACTIONS
Post-Marketing Experience
- Hepatobiliary Disorders: hepatic failure (some fatal), jaundice, serious cases of abnormal liver function test results, liver disorder.
January 2011
4 CONTRAINDICATIONS
ULORIC is contraindicated in patients being treated with azathioprine, or mercaptopurine, ("or theophylline" removed) [see Drug Interactions (7)].
6 ADVERSE REACTIONS
6.2 Postmarketing Experience
Adverse reactions have been identified during post approval use of ULORIC. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship.
Immune System Disorders: anaphylaxis, anaphylactic reaction.
Musculoskeletal and Connective Tissue Disorders: rhabdomyolysis.
Psychiatric Disorders: psychotic behavior including aggressive thoughts.
Renal and Urinary Disorders: tubulointerstitial nephritis
Skin and Subcutaneous Tissue Disorders: generalized rash, Stevens Johnson Syndrome, hypersensitivity skin reactions.
7 DRUG INTERACTIONS
7.1 Xanthine Oxidase Substrate Drugs
- ULORIC is an XO inhibitor. Based on a drug interaction study in healthy subjects, febuxostat altered the metabolism of theophylline (a substrate of XO) in humans [see Clinical Pharmacology (12.3)]. Therefore, use with caution when co-administering ULORIC.
Drug interaction studies of ULORIC with other drugs that are metabolized by XO (e.g., mercaptopurine and azathioprine) have not been conducted. Inhibition of XO by ULORIC may cause increased plasma concentrations of these drugs leading to toxicity [see Clinical Pharmacology (12.3)]. ULORIC is contraindicated in patients being treated with azathioprine, or mercaptopurine [see Contraindications (4)].







