WARNINGS
Suicide Risk
- Do not prescribe Rybix ODT for patients who are suicidal or addiction-prone
- Prescribe RYBIX ODT with caution for patients who are taking tranquilizers or antidepressant drug and patients who use alcohol in excess and who suffer from emotional disturbance or depression.
- The judicious prescribing of tramadol is essential to the safe use of this drug. With patients who are depressed or suicidal, consideration should be given to the use of nonnarcotic analgesics.
- Tramadol-related deaths have occurred in patients with previous histories of emotional disturbances or suicidal ideation or attempts as well as histories of misuse of tranquilizers, alcohol, and other CNS active drugs
Serotonin Syndrome Risk
- The development of a potentially life-threatening serotonin syndrome may occur with the use of tramadol products, including Rybix ODT, particularly with concomitant use of serotonergic drugs such as SSRIs, SNRIs, TCAs, MAOIs, and triptans, with drugs which impair metabolism of tramadol (CYP2D6 and CYP3A4 inhibitors). This may occur within the recommended dose
- Serotonin syndrome may include mental-status changes (e.g., agitation, hallucinations, coma), autonomic instability (e.g., tachycardia, labile blood pressure, hyperthermia), neuromuscular aberrations (e.g., hyperreflexia, incoordination) and/or gastrointestinal symptoms (e.g., nausea, vomiting, diarrhea).
Interaction With the Central Nervous System (CNS) Depressants
- Interactions with Alcohol and Drugs of Abuse: Tramadol may be expected to have additive effects when used in conjunction with alcohol, other opioids, or illicit drugs that cause central nevous system depression.
- Misuse, Abuse and Diversion: Tramadol has mu-opioid agonist activity. Rybix ODT can be sought by drug abusers and people with addiction disorders and may be subject to criminal diversion. The possibility of illegal or illicit use should be considered when prescribing or dispensing RYBIX ODT in situations where the physician or pharmacist is concerned about an increased risk of misuse, abuse, or diversion. Misuse or abuse poses a significant risk to the abuser that could result in overdose and death.
PRECAUTIONS
Information for Patients
- Patients should be informed that Rybix ODT may cause seizures and/or serotonin syndrome with concomitant use of serotonergic agents (including SSRIs, SNRIs, and triptans) or drugs that significantly reduce the metabolic clearance of tramadol.
Drug Interactions
- CYP2D6 and CYP3A4 Inhibitors: Concomitant administration of CYP2D6 and/or CYP3A4 inhibitors such as quinidine, fluoxetine, paroxetine and amitriptyline (CYP2D6 inhibitors), and ketoconazole and erythromycin (CYP3A4 inhibitors), may reduce metabolic clearance of tramadol increasing the risk for serious adverse events including seizures and serotonin syndrome.
- Serotonergic Drugs: There have been postmarketing reports of serotonin syndrome with use of tramadol and SSRIs/SNRIs or MAOIs and α2-adrenergic blockers. Caution is advised when RYBIX ODT is coadministered with other drugs that may affect the serotonergic neurotransmitter systems, such as SSRIs, MAOIs, triptans, linezolid (an antibiotic which is a reversible non-selective MAOI), lithium, or St. John’s Wort...
- Triptans: Based on the mechanism of action of tramadol and the potential for serotonin syndrome, caution is advised when RYBIX ODT is coadministered with a triptan. If concomitant treatment of RYBIX ODT with...
-
-