Safety
Baraclude (entecavir) Tablets and Oral Solution July 2008
Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER) -- July 2008
| The detailed view includes drug products with safety labeling changes to the BOXED WARNING, CONTRAINDICATIONS, WARNINGS, PRECAUTIONS, ADVERSE REACTIONS, or PATIENT PACKAGE INSERT/MEDICATION GUIDE sections. Deletions or editorial revisions made to these sections are not included in this summary. |
| Sections Modified | Summary of Changes to Contraindications and Warnings |
|
BOXED WARNING
WARNINGS AND PRECAUTIONS
ADVERSE REACTIONS
USE IN SPECIFIC POPULATIONS
PATIENT COUNSELING INFORMATION
|
BOXED WARNING (the following headed added) WARNINGS: SEVERE ACUTE EXACERBATIONS OF HEPATITIS B, PATIENTS CO-INFECTED WITH HIV AND HBV, and LACTIC ACIDOSIS AND HEPATOMEGALY WARNINGS AND PRECAUTIONS Lactic Acidosis and Severe Hepatomegaly with Steatosis (new subsection) Lactic acidosis and severe hepatomegaly with steatosis, including fatal cases, have been reported with the use of nucleoside analogues alone or in combination with antiretrovirals. A majority of these cases have been in women. Obesity and prolonged nucleoside exposure may be risk factors. Particular caution should be exercised when administering nucleoside analogues to any patient with known risk factors for liver disease; however, cases have also been reported in patients with no known risk factors. Treatment with Baraclude should be suspended in any patient who develops clinical or laboratory findings suggestive of lactic acidosis or pronounced hepatotoxicity (which may include hepatomegaly and steatosis even in the absence of marked transaminase elevations). |