-

Safety

  • Share Share this page

Cipro (ciprofloxacin) Prescribing Information and Medication Guide Oct 2008

Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER) -- October 2008

 

The detailed view includes drug products with safety labeling changes to the BOXED WARNING, CONTRAINDICATIONS, WARNINGS, PRECAUTIONS, ADVERSE REACTIONS, or PATIENT PACKAGE INSERT/MEDICATION GUIDE sections. Deletions or editorial revisions made to these sections are not included in this summary. Read about the new physician labeling format.


Summary View

 

Sections Modified

Summary of Changes to Contraindications and Warnings

BOXED WARNING (new)

WARNINGS

  • Tendinopathy and Tendon Rupture

PRECAUTIONS

  • Information for Patients
    • Patients should be advised:
      • to contact their healthcare provider if they experience pain, swelling, or inflammation of a tendon, or weakness or inability to use one of their joints; rest and refrain from exercise; and discontinue Cipro XR treatment. The risk of severe tendon disorder with fluoroquinolones is higher in older patients usually over 60 years of age, in patients taking corticosteroid drugs, and in patients with kidney, heart or lung transplants...
  • Geriatric Use
    • Geriatric patients are at increased risk for developing severe tendon disorders including tendon rupture when being treated with a fluoroquinolone such as Cipro XR...

MEDICATION GUIDE (new)

BOXED WARNING

WARNING: Fluoroquinolones, including Cipro XR, are associated with an increased risk of tendinitis and tendon rupture in all ages. This risk is further increased in older patients usually over 60 years of age, in patients taking corticosteroid drugs, and in patients with kidney, heart or lung transplants (See WARNINGS).

WARNINGS

Tendinopathy and Tendon Rupture: Fluoroquinolones, including Cipro XR, are associated with an increased risk of tendinitis and tendon rupture in all ages. This adverse reaction most frequently involves the Achilles tendon, and rupture of the Achilles tendon may require surgical repair. Tendinitis and tendon rupture in the rotator cuff (the shoulder), the hand, the biceps, the thumb, and other tendon sites have also been reported. The risk of developing fluoroquinolone-associated tendinitis and tendon rupture is further increased in older patients usually over 60 years of age, in patients taking corticosteroid drugs, and in patients with kidney, heart or lung transplants. Factors, in addition to age and corticosteroid use, that may independently increase the risk of tendon rupture include strenuous physical activity, renal failure, and previous tendon disorders such as rheumatoid arthritis. Tendinitis and tendon rupture have also occurred in patients taking fluoroquinolones who do not have the above risk factors. Tendon rupture can occur during or after completion of therapy; cases occurring up to several months after completion of therapy have been reported. Cipro XR should be discontinued if the patient experiences pain, swelling, inflammation or rupture of a tendon. Patients should be advised to rest at the first sign of tendinitis or tendon rupture, and to contact their healthcare provider regarding changing to a non-quinolone antimicrobial drug.

    
-
-
-
-
-