Safety
Aldactone (spironolactone tablets, USP)
Detailed View: Safety Labeling Changes Approved By FDA Center for Drug Evaluation and Research (CDER) -- November 2008
| The detailed view includes drug products with safety labeling changes to the BOXED WARNING, CONTRAINDICATIONS, WARNINGS, PRECAUTIONS, ADVERSE REACTIONS, or PATIENT PACKAGE INSERT/MEDICATION GUIDE sections. Deletions or editorial revisions made to these sections are not included in this summary. Read about the new physician labeling format. |
| Sections Modified |
Summary of Changes to Contraindications and Warnings |
|
WARNINGS
|
WARNINGS Hyperkalemia in patients with severe heart failure: Hyperkalemia may be fatal. It is critical to monitor and manage serum potassium in patients with severe heart failure receiving Aldactone. Avoid using other potassium-sparing diuretics. Avoid using oral potassium supplements in patients with serum potassium > 3.5 mEq/L. RALES excluded patients with a serum creatinine > 2.5 mg/dL or a recent increase in serum creatinine > 25%. The recommended monitoring for potassium and creatinine is one week after initiation or increase in dose of Aldactone, monthly for the first 3 months, then quarterly for a year, and then every 6 months. Discontinue or interrupt treatment for serum potassium > 5 mEq/L or for serum creatinine > 4 mg/dL. (See CLINICAL STUDIES, Severe heart failure, and DOSAGE AND ADMINISTRATION, Severe heart failure.) |