Medtronic® InSync® ICD Model 7272 Dual Chamber Implantable Cardioverter Defibrillator System with Cardiac Resynchronization Therapy - P010031

This is a brief overview of information related to FDA's approval to market this product. See the links below to the Summary of Safety and Effectiveness and product labeling for more complete information on this product, its indications for use, and the basis for FDA's approval.


Product Name: Medtronic® InSync® ICD Model 7272 Dual Chamber Implantable Cardioverter Defibrillator System with Cardiac Resynchronization Therapy
Manufacturer:
Medtronic, Inc.
Address:
710 Medtronic Parkway, Minneapolis, MN 55432
Approval Date:
June 26, 2002
Approval Letter: 
http://www.accessdata.fda.gov/cdrh_docs/pdf/p010031a.pdf

What is it and how does it work? The InSync® ICD System is an implantable cardioverter defibrillator (ICD) that also delivers cardiac resynchronization therapy (CRT) for certain patients with advanced heart failure. The system consists of an implantable device, made up of a battery and electronic circuitry, connected to three leads (insulated wires). The pulse generator is usually implanted below the collarbone, just beneath the skin. One lead is placed in an upper heart chamber (the right atrium) and the two other leads are placed in each of the lower heart chambers (the ventricles). When the device is functioning as an ICD, it senses dangerous abnormal heart rhythms and shocks the heart back into a normal rhythm. The CRT portion of the device coordinates the beating of the left and right ventricles so that they work together more effectively to pump blood throughout the body.

When is it used? In certain patients who are at risk for life-threatening heart rhythm problems and also have symptoms of advanced heart failure despite taking heart failure medication. Symptoms of heart failure such as fatigue, shortness of breath and difficulty performing daily activities, are caused by the heart not pumping enough blood to meet the body's needs. In some of these patients, the lower heart chambers do not contract together and CRT helps coordinate the beating of the heart.

What will it accomplish? This device system will deliver a life-saving shock to return the heart to normal heart rhythm and prevent sudden cardiac death. It may also relieve some of the symptoms associated with heart failure, including shortness of breath and fatigue during exercise, and this may result in a better quality of life.

When should it not be used? It should not be used in patients whose heart failure or life-threatening heart rhythm abnormality are reversible or temporary. It should not be used on those patients who are not on the appropriate drugs for heart failure.

Additional information: Summary of Safety and Effectiveness and labeling will be available at: http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cftopic/pma/pma.cfm?num=p010031